Quizzes
Take Quizzes
Animal
Nutrition
Love
Relationship
Computer
Sports
Society
Business
Geography
Language
Personality
Harry Potter
Movie
Television
Music
Online Exam
Health
Country
Art
Entertainment
Celebrity
Math
Game
Book
Fun
Science
Food
History
Education
All Topics
Create a Quiz
Quiz Maker
Training Maker
Survey Maker
Flashcards
Brain Games
See All
ProProfs.com
Search
Create A Quiz
Take Quizzes
Animal
Nutrition
Love
Relationship
Computer
Sports
Society
Business
Geography
Language
Personality
Harry Potter
Movie
Television
Music
Online Exam
Health
Country
Art
Entertainment
Celebrity
Math
Game
Book
Fun
Science
Food
History
Education
All Topics
Products
Quiz Maker
Training Maker
Survey Maker
Flashcards
Brain Games
See All
ProProfs.com
Quizzes
Quizzes
›
Professional Certification
›
CDC
Vol1 Ure3 CDC 3D153
27 Questions
|
By Jayhuiz23 | Updated: Mar 21, 2022
| Attempts: 76
Share
Quiz
Flashcard
Start
Share on Facebook
Share on Twitter
Share on Whatsapp
Share on Pinterest
Share on Email
Copy to Clipboard
Embed on your website
Question
1
/ 28
🏆
Rank #--
▾
0 %
0/100
Score
0/100
1.
(017) When testing a diode with the 8025A, the leads across a "good" diode produces an "OL" (open) on the display in one direction while reversing the leads produces?
A continuous audible tone
"SL" (short) on the display
A wavering audible tone
Three short beeps
Submit
Start Quiz
About This Quiz
This is Unit Review Exercise 3 for AFSC 3D153. This is to be used as a study aid.
2.
What first name or nickname would you like us to use?
You may optionally provide this to label your report, leaderboard, or certificate.
2.
(020) What area of a digital storage oscilloscope takes digitized samples and performs numerous manipulations on the data including measuring rise and fall times, periods, time intervals, and math computations?
Microprocessors
Acquisition
Memory
Input
Submit
3.
System grounds must continually be tested how often?
Randomly
Periodically
Every 10 years
Just one time only
Submit
4.
(017) Which current range on the Fluke 8025A do you select to measure 250 milliamps alternating current (AC)?
Microamps direct current (DC)
Microamps AC
Milliamps/amp DC
Milliamps/amp AC
Submit
5.
(022) Which of these bit rates do you use for a bit error rate test on a 64Kbps data circuit?
511 bps
9,600 bps
64 Kbps
1.544 Mbps
Submit
6.
(016) Which feature of the Fluke 8025A locks the measurement into the display for viewing and automatically updates the display when you take a new measurement?
Rotary Switch
Range push button
Power-up self test
Touch-hold push button
Submit
7.
(018) How are voltage, time, and depth represented on the oscilloscope display?
Voltage = intensity, time = vertical axis, and depth = horizontal axis
Voltage = intensity, time = horizontal axis, and depth = vertical axis
Voltage = horizontal axis, time = vertical axis, and depth = intensity
Voltage = vertical axis, time = horizontal axis, and depth = intensity
Submit
8.
(020) What type of sampling does a digital storage oscilloscope normally use on single-shot or seldom-occurring signals?
Sequential
Repetitive
Real-time
Random
Submit
9.
(020) In acquiring a 4K record length on a digital storage oscilloscope, how many samples can you view at one time?
1k
2k
3k
4k
Submit
10.
(018) Which mode of triggering an oscilloscope causes a trace to be drawn on the screen at all times, whether there is an input signal or not?
Auto
Norm
External
Source
Submit
11.
(021) What test equipment provides a bit error detection system that can determine the received data quality after traveling over a communications link?
Megger
Multimeter
Oscilloscope
Bit error rate (BER)
Submit
12.
What Protocol analyzer test window reports errors that occur at the physical layer such as bad fram check sequences (FSC), Short frames, and jabbers?
Bill Buchbinder "How Doom"
Media access control (MAC) node statistics
Protocol Statistics
Intertranslation through deviation of the node and all its aspects and characteristics of the node
Submit
13.
(020) Sampled data points are stored in the memory of a digital storage oscilloscope as?
Sequential records
Waveform points
Record lengths
Record points
Submit
14.
On the bit error rate test (BER) set, the 25-pin connectors are designed to operate with data modems to?
Simplify connection of test equipment to modem under test and to transmit the test pattern
Simplify connection of test equipment to the modem under test and to carry the necessary signaling and handshake signals for...
Simplify connection of test equipment to the modem under test and to carry the necessary signaling and handshake signals for modem operations
Isolate test equipment from the data circuit under test and to transmit the test pattern
Isolate test equipment from the data circuit under test and to carry the necessary signaling and to handshake signals for...
Isolate test equipment from the data circuit under test and to carry the necessary signaling and to handshake signals for modem operations
Submit
15.
(021) What pattern simulator section of the bit error rate test set accepts a 48-bit parallel word and generates a serial pattern?
48-bit transmitter only
Pseudo random noise (PRN) generator
Pseudo random noise (PRN) comparator
48-bit register and 8-bit word display
Submit
16.
What active test is selected to see the path that the packets are traveling and the time it takes the packets to complete the trip?
Pack Internetwork Groper (PING)
Trace Route
Traffic Generator
Route Generator
Submit
17.
What component on a protocol analyzer process the frames based on the selected test and user configuration inputs?
Counter
Buffer
Central Processing Unit (CPU)
Filter
Submit
18.
(019) Which probe does not need to actually make contact with the circuit under test?
Current Probe
Passive 1:1 probe
Active (FET) probe
Passive divider, 10:1 probe
Submit
19.
(020) In real-time sampling, what type of interpolation is used when measuring pulse waves?
Sine
Linear
Non-uniform
Companding
Submit
20.
The Institute of Electrical and Electronics Engineers (IEEE) have recommended a ground resistance value of?
5 ohms or less
10 ohms or less
15 ohms or less
25 ohms or less
Submit
21.
(024) A known current is generated by the earth ground tester between the earth ground electode and the ?
Grounding point
Inner earth stake Y
Auxiliary current probe
Auxiliary potential probe
Submit
22.
What protocol analyzer test window provides information concerning the network utilization and frame error that are related to a specific protocol?
Media Access control (MAC) node statistics
Connection statistics
Protocol Statistics
Node discovery
Submit
23.
(020) What digital storage oscilloscope circuit compensates for high sampling rates of high frequency signals?
Analog-to-digital converter
Digital-to-analog converter
Charged coupled device
Cathode-ray tube
Submit
24.
(020) Which are the three types of digital storage oscilloscope acquisition modes, and which is the standard operating mode?
Sample, peak detect, averaging; sample.
Real-time, peak detect, sample; real-time.
Real-time, peak detect, sample; averaging
Sample, peak detect, averaging; peak detect
Submit
25.
What pattern simulator section of the bit error rate test set converts the non-return zero level (NRZ-L) data into the desired coding, such as non-return 0-mark (NRZ-M)?
Data Drivers
Code Converter
External Data Comparator
Psuedo Random Noise (PRN) Generator
Submit
26.
Where is voltage potential measured in the fall of potential ground testing method?
Between the auxiliary potential electrode and the earth ground electrode
Between the auxiliary current electrode and the earth ground electrode
Between the auxiliary potential and auxiliary current electrodes
Between the earth ground electrode and the outer stake Z
Submit
27.
(021) What pattern syncronizer and error counter section of the bit error rate test set internally generates its own pattern to compare with the received data from the data/clock receivers?
48-transmitter only
48-bit synchronizer/comparator
External data pattern synchronizer/comparator
Pseudo ramdom noise (PRN) generator
Submit
×
Thank you for your feedback!
View My Results
Related Quizzes
4N051 CDC Set A Practice Test
4N051 CDC Set A Practice Test
CDC 2AX7X: Air Force EOC Test! Trivia Quiz
CDC 2AX7X: Air Force EOC Test! Trivia Quiz
7 Level CDC 2t2 Vol 1
7 Level CDC 2t2 Vol 1
CDC 3S071 Volume 1. Personnel Career Field, Edit Code 02
CDC 3S071 Volume 1. Personnel Career Field, Edit Code 02
CDC 2AX7X (Vol. 1: 01 1201, Edit Code 5 -- Vol. 2: 02 1110, Edit Code 05) Ure's
CDC 2AX7X (Vol. 1: 01 1201, Edit Code 5 -- Vol. 2: 02 1110, Edit Code 05) Ure's
2T271 CDC Practice Test Vol. 2
2T271 CDC Practice Test Vol. 2
Thank you for your feedback!
Would you like to edit this question to improve it?
No thanks
Name:
Email:
Oops! Give us more information:
Incorrect Question
Incorrect Answer
Typos
I have a feedback
Submit
Please provide name and email to proceed.
Please provide correct email to proceed.
Please provide feedback.
Please select the option.
All (27)
Unanswered (
)
Answered (
)
(017) When testing a diode with the 8025A, the leads across a "good"...
(020) What area of a digital storage oscilloscope takes digitized...
System grounds must continually be tested how often?
(017) Which current range on the Fluke 8025A do you select to measure...
(022) Which of these bit rates do you use for a bit error rate test on...
(016) Which feature of the Fluke 8025A locks the measurement into the...
(018) How are voltage, time, and depth represented on the oscilloscope...
(020) What type of sampling does a digital storage oscilloscope...
(020) In acquiring a 4K record length on a digital storage...
(018) Which mode of triggering an oscilloscope causes a trace to be...
(021) What test equipment provides a bit error detection system that...
What Protocol analyzer test window reports errors that occur at the...
(020) Sampled data points are stored in the memory of a digital...
On the bit error rate test (BER) set, the 25-pin connectors are...
(021) What pattern simulator section of the bit error rate test set...
What active test is selected to see the path that the packets are...
What component on a protocol analyzer process the frames based on the...
(019) Which probe does not need to actually make contact with the...
(020) In real-time sampling, what type of interpolation is used when...
The Institute of Electrical and Electronics Engineers (IEEE) have...
(024) A known current is generated by the earth ground tester between...
What protocol analyzer test window provides information concerning the...
(020) What digital storage oscilloscope circuit compensates for high...
(020) Which are the three types of digital storage oscilloscope...
What pattern simulator section of the bit error rate test set converts...
Where is voltage potential measured in the fall of potential ground...
(021) What pattern syncronizer and error counter section of the bit...
X
OK
X
OK
Cancel
X
OK
Cancel
Your Rank: #-- / --
Leaderboard
✕