Vol1 Ure3 CDC 3D153

27 Questions | Attempts: 76
Please wait...
Question 1 / 28
🏆 Rank #--
Score 0/100

1. (017) When testing a diode with the 8025A, the leads across a "good" diode produces an "OL" (open) on the display in one direction while reversing the leads produces?

Submit
Please wait...
About This Quiz
CDC Quizzes & Trivia

This is Unit Review Exercise 3 for AFSC 3D153. This is to be used as a study aid.

2.

What first name or nickname would you like us to use?

You may optionally provide this to label your report, leaderboard, or certificate.

2. (020) What area of a digital storage oscilloscope takes digitized samples and performs numerous manipulations on the data including measuring rise and fall times, periods, time intervals, and math computations?

Submit

3. System grounds  must continually be tested how often?

Submit

4. (017) Which current range on the Fluke 8025A do you select to measure 250 milliamps alternating current (AC)?

Submit

5. (022) Which of these bit rates do you use for a bit error rate test on a 64Kbps data circuit?

Submit

6. (016) Which feature of the Fluke 8025A locks the measurement into the display for viewing and automatically updates the display when you take a new measurement?

Submit

7. (018) How are voltage, time, and depth represented on the oscilloscope display?

Submit

8. (020) What type of sampling does a digital storage oscilloscope normally use on single-shot or seldom-occurring signals?

Submit

9. (020) In acquiring a 4K record length on a digital storage oscilloscope, how many samples can you view at one time?

Submit

10. (018) Which mode of triggering an oscilloscope causes a trace to be drawn on the screen at all times, whether there is an input signal or not?

Submit

11. (021) What test equipment provides a bit error detection system that can determine the received data quality after traveling over a communications link?

Submit

12. What Protocol analyzer test window reports errors that occur at the physical layer such as bad fram check sequences (FSC), Short frames, and jabbers?

Submit

13. (020) Sampled data points are stored in the memory of a digital storage oscilloscope as?

Submit

14. On the bit error rate test (BER) set, the 25-pin connectors are designed to operate with data modems to?

Submit

15. (021) What pattern simulator section of the bit error rate test set accepts a 48-bit parallel word and generates a serial pattern?

Submit

16. What active test is selected to see the path that the packets are traveling and the time it takes the packets to complete the trip?

Submit

17. What component on a protocol analyzer process the frames based on the selected test and user configuration inputs?

Submit

18. (019) Which probe does not need to actually make contact with the circuit under test?

Submit

19. (020) In real-time sampling, what type of interpolation is used when measuring pulse waves?

Submit

20. The Institute of Electrical and Electronics Engineers (IEEE) have recommended a ground resistance value of?

Submit

21. (024) A known current is generated by the earth ground tester between the earth ground electode and the ?

Submit

22. What protocol analyzer test window provides information concerning the network utilization and frame error that are related to a specific protocol?

Submit

23. (020) What digital storage oscilloscope circuit compensates for high sampling rates of high frequency signals?

Submit

24. (020) Which are the three types of digital storage oscilloscope acquisition modes, and which is the standard operating mode?

Submit

25. What pattern simulator section of the bit error rate test set converts the non-return zero level (NRZ-L) data into the desired coding,  such as non-return 0-mark (NRZ-M)?

Submit

26. Where is voltage potential measured in the fall of potential ground testing method?

Submit

27. (021) What pattern syncronizer and error counter section of the bit error rate test set internally generates its own pattern to compare with the received data from the data/clock receivers?

Submit
×
Saved
Thank you for your feedback!
View My Results
Cancel
  • All
    All (27)
  • Unanswered
    Unanswered ()
  • Answered
    Answered ()
(017) When testing a diode with the 8025A, the leads across a "good"...
(020) What area of a digital storage oscilloscope takes digitized...
System grounds  must continually be tested how often?
(017) Which current range on the Fluke 8025A do you select to measure...
(022) Which of these bit rates do you use for a bit error rate test on...
(016) Which feature of the Fluke 8025A locks the measurement into the...
(018) How are voltage, time, and depth represented on the oscilloscope...
(020) What type of sampling does a digital storage oscilloscope...
(020) In acquiring a 4K record length on a digital storage...
(018) Which mode of triggering an oscilloscope causes a trace to be...
(021) What test equipment provides a bit error detection system that...
What Protocol analyzer test window reports errors that occur at the...
(020) Sampled data points are stored in the memory of a digital...
On the bit error rate test (BER) set, the 25-pin connectors are...
(021) What pattern simulator section of the bit error rate test set...
What active test is selected to see the path that the packets are...
What component on a protocol analyzer process the frames based on the...
(019) Which probe does not need to actually make contact with the...
(020) In real-time sampling, what type of interpolation is used when...
The Institute of Electrical and Electronics Engineers (IEEE) have...
(024) A known current is generated by the earth ground tester between...
What protocol analyzer test window provides information concerning the...
(020) What digital storage oscilloscope circuit compensates for high...
(020) Which are the three types of digital storage oscilloscope...
What pattern simulator section of the bit error rate test set converts...
Where is voltage potential measured in the fall of potential ground...
(021) What pattern syncronizer and error counter section of the bit...
play-Mute sad happy unanswered_answer up-hover down-hover success oval cancel Check box square blue