Swimming Pools Based On 2008 Nec

Approved & Edited by ProProfs Editorial Team
The editorial team at ProProfs Quizzes consists of a select group of subject experts, trivia writers, and quiz masters who have authored over 10,000 quizzes taken by more than 100 million users. This team includes our in-house seasoned quiz moderators and subject matter experts. Our editorial experts, spread across the world, are rigorously trained using our comprehensive guidelines to ensure that you receive the highest quality quizzes.
Learn about Our Editorial Process
| By Etniaei
E
Etniaei
Community Contributor
Quizzes Created: 1 | Total Attempts: 504
Questions: 9 | Attempts: 504

SettingsSettingsSettings
Swimming Pools Based On 2008 Nec - Quiz




How much do you know about 2008 NEC requirements for swimming pools?
Take this short quiz and find out.


Questions and Answers
  • 1. 

    Which of the following is regulated by Article 680?

    • A.

      Fish Farm Pond

    • B.

      Church Baptistry

    • C.

      Storm Retention Basin

    • D.

      None of the above

    Correct Answer
    B. Church Baptistry
    Explanation
    Article 680.2 now lists pools for immersion under its scope.

    Rate this question:

  • 2. 

    Underground wiring within 5 feet horizontally from the inside wall of the pool shall be:

    • A.

      Sleeved

    • B.

      A cable assembly listed for direct burial

    • C.

      In a complete raceway

    • D.

      Any of these

    Correct Answer
    C. In a complete raceway
    Explanation
    Article 680.10 - "Where space limitations prevent wiring from being routed a distance 1.5m (5 ft) or more from the pool, such wiring shall be permitted where installed in a complete raceway..."

    Rate this question:

  • 3. 

    Which of the following pool pump motors are required to be GFCI protection?

    • A.

      Cord and plug connected motors

    • B.

      Directly connected motors

    • C.

      240 volt motors

    • D.

      All of the above

    Correct Answer
    D. All of the above
    Explanation
    Article 680.22(B) "Outlets supplying pool pump motors from branch-circuits with short-circuit and ground-fault protection rated 15 or 20 amperes, 125 volt or 240 volt, single phase, whether by receptacle or direct connection, shall be provided with ground-fault circuit-interrupter protection for personnel."

    Rate this question:

  • 4. 

    Receptacles shall be a minimum of ______ feet from the inside wall of a pool.

    • A.

      6

    • B.

      8

    • C.

      10

    • D.

      20

    Correct Answer
    A. 6
    Explanation
    Article 680.22(A)(1)(2)(3)- "Receptacles shall not be less than 1.83m (6 ft) from the inside walls of a pool."

    Rate this question:

  • 5. 

    A junction box connected to a conduit that extends directly to a pool light shall be:

    • A.

      Listed

    • B.

      Identified

    • C.

      Labeled

    • D.

      Brass

    Correct Answer
    A. Listed
    Explanation
    Article 680.24(A)(1)- "The junction box shall be listed as a swimming pool junction box..."

    Rate this question:

  • 6. 

    Which of the following raceways cannot be used to feed a panel in the pool area?

    • A.

      Rigid metal conduit

    • B.

      IMC conduit

    • C.

      Rigid Aluminum conduit

    • D.

      Liquidtight Flexible Nonmetallic conduit

    Correct Answer
    C. Rigid Aluminum conduit
    Explanation
    Article 680.25(A)- "Aluminum conduits shall not be permitted in the pool area where subject to corrosion."

    Rate this question:

  • 7. 

    Where there is no structural reinforcing steel installed in the pool deck, bonding can be provided by installing a single solid 8 AWG copper conductor around the perimeter.

    • A.

      True

    • B.

      False

    Correct Answer
    A. True
    Explanation
    Article 680.26(B)(2)(b)Alternate Means

    Rate this question:

  • 8. 

    A double-insulated pool water pump motor does not require a bonding conductor to be extended to it.

    • A.

      True

    • B.

      False

    Correct Answer
    B. False
    Explanation
    Article 680.26(B)(6)(a)- A bonding conductor is required to be run to motor location for replacement purposes.

    Rate this question:

  • 9. 

    Where the pool water is isolated by an insulated pool shell (eg. fiberglass or vinyl) and there are no conductive elements such as ladders, railings, etc. in contact with the water, the pool water itself is not required to be bonded to the equipotential grid.

    • A.

      True

    • B.

      False

    Correct Answer
    B. False
    Explanation
    Article 680.26(C)- "An intentional bond of a minimum conductive surface area of 5806 sq. mm (9 sq. inches) shall be installed in contact with the pool water.

    Rate this question:

Quiz Review Timeline +

Our quizzes are rigorously reviewed, monitored and continuously updated by our expert board to maintain accuracy, relevance, and timeliness.

  • Current Version
  • Mar 15, 2023
    Quiz Edited by
    ProProfs Editorial Team
  • Jul 15, 2008
    Quiz Created by
    Etniaei
Back to Top Back to top
Advertisement
×

Wait!
Here's an interesting quiz for you.

We have other quizzes matching your interest.