This quiz assesses knowledge in the operation and maintenance of hydrant systems within the Air Force, focusing on control mechanisms, system diagnostics, and troubleshooting common issues. It is essential for personnel involved in direct fuel handling and infrastructure maintenance.
System pressure and issue flow rate
System pressure and issue/return flow rates
Issue/return flow rates and tank liquid level
Filter/separator differential pressure and tank liquid level
Rate this question:
Electrical shorts
No fuel delivery
Minor leaks
Jammed valves
Rate this question:
1
2
3
4
Rate this question:
Ejector strainer
CV flow control
Pressure relief control
Pressure-reducing control
Rate this question:
An uncontrolled downstream flow
A fuel leakage from the vent port
Uncontrolled downstream pressure
Fuel leaking from the disc removal plug
Rate this question:
CRD
CDHS-3
Loaded CRL
CV flow control
Rate this question:
Pressure to operate the CDHS-2
Pressure to operate the CDHS-3
Flow to operate the CDHS-2
Flow to operate the CDHS-3
Rate this question:
Loaded CRL
CDHS-3
Solenoid
Hytrol
Rate this question:
Pressure-reducing control (CRD) closkwise
Loading pressure-relief control (CRL) clockwise
CRD counterclockwise
Loading CRL counterclockwise
Rate this question:
5 psi above normal inlet pressure
5 psi above normal operating pressure
10 psi above normal inlet pressure
10 psi above normal operating pressure
Rate this question:
10 seconds
20 seconds
30 seconds
40 seconds
Rate this question:
The 302AF electrical solenoid only
The deep-well pump only
The 302AF solenoid and the defueling pump
The deep-well turbine pump and the 302AF electrical solenoid
Rate this question:
The coupling poppet
The vacuum breaker
The flange gasket
The solenoid
Rate this question:
1
2
3
4
Rate this question:
Refueling control valve and defueling valve are energized
Defueling control valve and the defueling pump are energized
Rate-of-flow control valve and defuel pump are energized
Defueling control valve and deep-well turbine pumps are energized
Rate this question:
Solenoid control switch
Pump circuit breaker
Vacuum control switch
Panel selector switch
Rate this question:
Pulsates
Modulates
Opens fully
Closes fully
Rate this question:
Pulsate
Modulate
Open fully
Close fully
Rate this question:
A and B close
A and B open
A opens and B closes
A closes and B opens
Rate this question:
5 pounds per square inch (psi) higher than the normal operating pressure
5 psi higher than the inlet pressure of the 90AF-8
5 psi higher than the 51AF-4
5 higher than the normal inlet pressure of the 51AF-4
Rate this question:
2 to 3 pounds per square inch (psi) above normal downstream pressure
2 to 3 psi above normal upstream pressure
5 psi above normal downstream pressure
5 psi above normal upstream pressure
Rate this question:
Auxiliary hytrol A closing
CDHS-3 tripping
Solenoid never energizing
Pressure relief control set too high
Rate this question:
The solenoid is not energized
A ruptured diaphragm in hytrol A
The CV flow control is not set properly
The pressure relief control is set too low
Rate this question:
Only the primary jet
Only the secondary jet
The primary and secondary jets
Neither the primary nor the secondary jets
Rate this question:
Yearly
Semi-annually
Quarterly
Monthly
Rate this question:
2 to 3 psi above its normal operating pressure
2 to 3 psi above its normal inlet pressure
10 psi above its normal operating pressure
10 psi above its normal inlet pressure
Rate this question:
Flow clean strainer,and ejector
Ejector, and pressure relief valve
Orifice strainer, and pressure relief valve
Ejector strainer, and pressure differential control
Rate this question:
Monthly
Quarterly
Semi-annually
Annually
Rate this question:
The 50AF-2 valve does not open
Hydrant pressure becomes very high
The defuel pump rotates slowly during refueling
The refueling valve opens and clsoes
Rate this question:
Ejector
Solenoid
Hytrol check
Differential control
Rate this question:
Clockwise for maximum spring tension
Clockwise for minimum spring tension
Counterclockwise for maximum spring tension
Counterclockwise for minimum spring tension
Rate this question:
Leakage through normally open solenoid valve
Leakage through normally closed solenoid valve
Leakage through solenoid valve during slow flow
Check valve installed backwards
Rate this question:
Keep moisture out of the system
Prevent corrosion in the piping system
Keep the fuel pressure from getting too high
Prevent air from entering the installed piping system
Rate this question:
15
25
35
45
Rate this question:
Placing the magnet on the refuel magnetic control station switch
Placing the cover back on the emergency switch
Manually resetting the controls in the lateral control pit
Manually resetting the controls in the pumphouse control room
Rate this question:
Tin
Black steel
Cast iron
Galvanized/Stainless steel
Rate this question:
Monthly
Quarterly
Semi-annually
Annually
Rate this question:
5 psi and 5 psi above the CRL on the 90AF-8
5 psi and 5 psi above the CRL on the 50AF-2
10 psi and 5 psi above the CRL on the 90AF-8
10 psi and 5 psi above the CRL on the 50AF-2
Rate this question:
Relieve excess pressure during refueling
Make sure the defuel piping stays full of fuel
Make sure the hydrant outlet line stays full of fuel
Prevent reverse flow during rapid flow defueling
Rate this question:
2 psi above normal operating pressure
3 psi above normal operating pressure
5 psi above normal operating pressure
10 psi above normal operating pressure
Rate this question:
Solenoid failed to deenergize
Solenoid failed to energize
CV-flow control
Low-pressure relief control
Rate this question:
Carbon steel, schedule 80S
Carbon steel, schedule 40S
Stainless steel, schedule 20S
Stainless steel, schedule 10S
Copper
Carbon
Galvanized
Stainless Steel
Rate this question:
3 psi
10 psi
15 psi
20 psi
Rate this question:
1529, 600 gpm
1529, 1200gpm
1581, 600 gpm
1581, 1200 gpm
15 psi is sensed across the receiving separator
15 psi is sensed across the orifice plate on the receiving separator
10 psi is sensed across the receiving separator
10 psi is sensed across the orifice plate on the receiving separator
Rate this question:
Reset the control panel
Clean the receiving strainer
Manually reset the 40-28G
Manually reset the CDHS-3A
Rate this question:
600 Positive
1200 Positive
600 Non-positive
1200 Non-positive
Rate this question:
Quiz Review Timeline (Updated): Mar 22, 2023 +
Our quizzes are rigorously reviewed, monitored and continuously updated by our expert board to maintain accuracy, relevance, and timeliness.