This quiz assesses knowledge on the EPU-6\/E frequency converter, focusing on operational troubleshooting, component inspection, and voltage regulation. It is designed for personnel involved in maintenance and operation of military electrical equipment.
Electrically.
Pneumatically.
Hydraulically.
By a belt off the engine crank shaft.
Rate this question:
Air inlets for blockage.
Wiring for secure mounting.
Maintenance panels for corrosion.
Interior air vents for secure mounting.
Rate this question:
Bypass.
28V to aircraft.
Loop.
Neutral.
Rate this question:
623.
457.
55.
2426.
Rate this question:
Supervisor.
Installation commander.
Uniform repair/replacement board.
Item management and the equipment specialist.
Rate this question:
Increase air pressure.
Decrease air velocity.
Smooth turbulent air flow.
Accelerate air.
Rate this question:
Powers the booster compressor.
Provides low pressure air for pneumatic tools.
Maintains 130°F air temperature to prevent condensation.
Provides air to the feed air compressor.
Rate this question:
Fuel safety switch.
Oil pressure switch.
Oil filter bypass valve.
Oil pressure relief valve.
Rate this question:
Open.
Blockage.
Condensing refrigerant.
Low refrigerant charge.
Rate this question:
Engine.
End of stroke limit switch.
Directional control valve cycling control relay.
Programmable logic controller (PLC) circuit.
Rate this question:
FCV1, FCV2.
CYL1, CYL2.
PS1, TS4, TS5.
ASM1, ASM2
Rate this question:
Inhibit switch.
Master switch.
Turbine Start switch.
Air Load switch.
Rate this question:
Replace SW2.
Replace the engine speed control.
Check the MPU to make sure it's sending the proper signal to the engine speed control.
Nothing; this is normal operation. The blower clutch energizes at governed speed.
Vacuum leaks.
Pressure leaks.
Outward leaks.
Inward leaks.
Rate this question:
Annually.
Prior to use.
Semiannually.
Daily.
Rate this question:
1 year.
18 months.
2 years.
30 months.
Rate this question:
Plenum.
Combustor cap.
Combustor can.
Torus assembly.
Rate this question:
Master switch.
Air load valve.
Air load switch.
Oil pressure switch.
Rate this question:
Interstage ducts.
Interstage seal.
Impellers.
Inducers
Rate this question:
Circulates the ethylene glycol/water solution.
Cools the ethylene glycol/water solution.
Cools discharge air from the blower.
Cools ambient air.
Rate this question:
Suction pressure is too high so the boiling point of the refrigerant must be decreased to decrease the output air temperature.
Air pressure is too low so the boiling point of the R134a must be increased.
Suction pressure is too low so the boiling point of the refrigerant must be increased to increase the output air temperature.
Suction air pressure is too high so the boiling point of the refrigerant can be decreased.
Rate this question:
The audible alarm switch is in the silence position.
The voltage control board potentiometer is shorted.
The ouput trim potentiometer is centered.
The analog board has failed.
Rate this question:
1 & 3
2 & 4
1, 2, and 3.
1, 3, and 4.
Rate this question:
Oil jet.
Oil cooler.
Scavange pump.
Oil tank vent line.
Rate this question:
Compressor.
Blower.
Evaporator.
Aftercooler.
Rate this question:
Equipment specialist.
Item manger.
MAJCOM HQ.
Uniform repair/replacement board.
Rate this question:
Malfunctioning transistor.
Improper SCR firing adjustment.
Burnt control transformer fuse.
Loose push-on connector on the output filter capacitor.
Rate this question:
K4 energized and its contacts closed.
K3 de-energized and its contacts opened.
K4 de-energized and its contacts closed.
K3 de-energized and the contacts did not remain closed.
Rate this question:
Plenum air pressure.
Fuel pressure.
Oil pressure.
Spring tension.
Rate this question:
B7 which steps closed to meter refrigerant into the evaporator.
B7 which steps open to meter refrigerant into the evaporator.
The quench valve which opens to aid in cooling.
S1 and S2 which open to aid in cooling.
Rate this question:
Override switch is not closed.
K7 contacts are closed.
Overspeed switch is closed.
Oil pressure switch is closed.
Rate this question:
Turbine start switch.
35 percent centrifugal speed switch.
Load switch.
Oil pressure switch.
Rate this question:
Input circuit breakers and display power supply.
Control transformer and voltage control.
SCR voltage regulator and phase sequence transformers.
Analog board and alarm display.
Rate this question:
Alternator output.
Oil pressure switch.
Ignition switch released.
Centrifugal switch opens.
Rate this question:
SV2.
S10.
TD2.
K6.
Rate this question:
CB3 is open.
S9 is shorted.
SV1 coil is open.
K7 is not energizing.
Rate this question:
Generator (G1).
Alternator (G2).
Transformer rectifier (TR1).
Power monitor relay (PMR)
Rate this question: