Designed for use in situations that require a special water discharge...
With the installation of residential fire sprinklers in one and two...
What section of NFPA defines automatic sprinkler systems?
Sprinklers is installed downward from the branch line so that water...
During installation of all fire-protection systems, the inspector...
Type of sprinkler that is specially painted or plated by the...
Designed to provide a means for rapidly deploying fire hoses and...
Used to limit the flow of water to one direction; placed in the water...
Type of sprinkler designed with an open orifice and no thermal or heat...
Type of sprinkler that is mounted horizontally from a wall face so...
Type of sprinkler activation device that depends on human intervention...
Type of sprinkler that is constructed of stainless steel or is factory...
Sprinkler system where the branch lines are not interconnected.
Type of sprinkler installed downward from the branch line so that...
Deluge or preaction type sprinklers operate:
Automatic sprinkler systems is continually charged with water under...
Type of water-based fire-suppression system & equipment designed...
How are sprinklers rated?
Standpipe system contains unpressurized air in pipes and has no...
Before performing any inspection, the inspector must:
Type of sprinkler designed specifically for use in high rack storage...
Type of sprinkler that is installed on a riser nipple above the branch...
The minimum sprinkler pipe size that may be used in a residential...
Sprinklers that are kept closed by fusible links or other thermally...
Water control valves has a hollow metal post attached to the valve...
Designed to control, contain or extinguish Class A or Class B firs and...
Generally, an inspector begins an inspection of a water-based...
Type of sprinkler designed for use in prisons, jails, or facilities...
Used to drain water from piping when pressure is relieved in the pipe;...
Type of sprinkler designed and listed to produce large water droplets;...
Sprinkler type that's designed to suppress fires in high-challenge...
A water supply for an automatic sprinkler system must maintain a...
Type of sprinkler that is recessed and covered with a removable...
Type of sprinkler designed to suppress fires in high challenge hazards...
Water-based fire-suppression system & equipment installed in...
Automatic sprinkler system valves is used to limit the flow of water...
Which of the following is the FIRST step in performing a main drain...
Private water mains are flow tested at a minimum of:
Type of sprinkler that is attached to a dry riser nipple that is...
One & two family dwellings, sprinklers can be omitted from:
Located on the riser and used to flow water for the purpose of testing...
Spacing for sprinklers in residential systems is a maximum of ____...
Automatic sprinkler system continually charged with air that may or...
Sprinkler system designed to operate repeatedly in response to a...
Sprinkler variations is designed to be damage resistant with no...
Type of sprinkler designed to cover an area 20 feet by 20 feet (6.1 m...
Which statement regarding the alarm trip test is MOST accurate?
Designed as small hand wheel type valves that typically turn...
Which MOST likely be used to protect computer equipment and rooms?
Type of sprinkler installed in a recessed housing within the ceiling...
A device for measuring temperature in which two electrical conductors...
Sprinklers that are mounted in a ceiling with the body of the...
Water supply for Class I & III standpipe systems must provide a...
Which method is designing water distribution pipe is MOST accurate?
Automatic sprinkler system continually charged with air or nitrogen...
Automatic sprinkler system valves is designed as small handwheel-type...
The most common method for driving a fire pump is:
Type of sprinkler activation device that activates preaction and dry...
Type of sprinkler activation device that activates an alarm on the...
Water-based fire suppression system & equipment designed to...
Automatic sprinkler system consists of open sprinklers attached to...
When inspecting water-flow control valves, an inspector should check...
Dry-pipe systems are hydrostatically tested every:
Standpipe system classifications is primarily for use by...
Stationary fire pumps is the most common type of fire pump found in...
Used for drains and alarm testing and sometimes known as STOP OR COCK...
Type of sprinkler designed to provide increased life safety in hotels,...
Sprinkler system is a wet-pipe system that uses the sprinkler system...
The water supply requirements for residential sprinklers are:
Which of the following statements about residential sprinklers is MOST...
Pressure-regulating devices are preferred for managing excessive...
Type of sprinkler mounted on a ceiling with the body of the sprinkler,...
Which of the following water control valves uses a butterfly valve?
Type of sprinkler designed to provide increased life safety in hotels,...
Residential sprinkler piping that is listed by an approved testing...
Type of sprinkler designed and listed to protect special hazards.
Residential sprinklers that protect an area as large as 20 x 20 feet -...
Pressure at which the pressure switch is set to start the fire pump...
When inspecting water spray fixed systems, an inspector should witness...
NFPA 13D requires ____ gpm for any size sprinkler. When there...
Distortion of a material caused by the repeated heating of a fusible...
Type of sprinkler designed for fast response in residential...
Which of the following types of stationary fire pumps is always driven...
Standpipe systems has the disadvantage of greater cost and maintenance...
Type of sprinkler activation device that activates based on the...
Type of sprinkler activation device that occurs when thermocouples...