The ProProfs editorial team is comprised of experienced subject matter experts. They've collectively created over 10,000 quizzes and lessons, serving over 100 million users. Our team includes in-house content moderators and subject matter experts, as well as a global network of rigorously trained contributors. All adhere to our comprehensive editorial guidelines, ensuring the delivery of high-quality content.
Learn about Our Editorial Process
| By Moroni_1
M
Moroni_1
Community Contributor
Quizzes Created: 2 | Total Attempts: 6,386
| Attempts: 212 | Questions: 96
Please wait...
Question 1 / 96
0 %
0/100
Score 0/100
1. A ceiling-mounted microphone is installed above the front(what)_________.

Explanation

A ceiling-mounted microphone is installed above the front serving counter and cash register. This placement allows the microphone to capture audio from both areas, ensuring that all conversations and transactions taking place at the serving counter and cash register can be easily recorded or monitored.

Submit
Please wait...
About This Quiz
Construction Management Quizzes & Trivia

CM 105 Wendy's Test assesses knowledge on construction management specifics, including contractor roles, material specifications, and structural details. It evaluates critical understanding and application of construction standards and project management essentials.

2. Type F grilles are (what) ________ in color.

Explanation

Type F grilles are white in color.

Submit
3. The distribution panelboard is installed in room(which)______.

Explanation

The distribution panelboard is installed in room 110, specifically in the dry storage area.

Submit
4. All bussing shall be (what)__________ only.

Explanation

The correct answer is "copper" because the blank space in the sentence is asking for the material that should be used for bussing. Copper is a commonly used material for bussing in electrical systems due to its high conductivity and durability.

Submit
5. Door elevation (which) _________ is referenced to doors A and D.

Explanation

The correct answer is "is lower". In door elevation, the term "lower" refers to the height of the door relative to a reference point. Therefore, when it is stated that the door elevation is referenced to doors A and D, it implies that the elevation of the door in question is lower than the elevations of doors A and D.

Submit
6. The sliding pick-up windows are shown on the (which side)_______ elevation.

Explanation

The sliding pick-up windows are shown on the left side elevation. This means that the windows are located on the left side of the structure when viewed from the outside.

Submit
7. Representing the footings and foundations are (what kind)________lines.

Explanation

The correct answer is "solid" because footings and foundations are typically represented using solid lines. Solid lines are used to indicate visible and physical components in architectural or engineering drawings. In contrast, dashed or dotted lines are used for hidden or non-physical elements. Therefore, solid lines are the appropriate choice for representing footings and foundations.

Submit
8. Type (what)______ registers are ceiling-mounted.

Explanation

not-available-via-ai

Submit
9. A 3” interceptor vent may be (what use)________ if it is not required by local code.

Explanation

If a 3" interceptor vent is not required by local code, it can be omitted. This means that it is not necessary to install or include this vent in the plumbing system. The term "omitted" refers to the act of leaving something out or excluding it. In this context, it suggests that the vent can be left out if it is not mandated by the local building regulations.

Submit
10. The local frost line is to be verified before digging foundation trenches.

Explanation

The local frost line needs to be verified before digging foundation trenches because the depth of the frost line determines how deep the foundation needs to be in order to avoid damage from freezing and thawing of the ground. If the foundation is not built below the frost line, it can be subjected to frost heave, which can cause significant structural damage. Therefore, it is important to verify the local frost line and dig the foundation trenches accordingly to ensure the stability and longevity of the structure.

Submit
11. The rough opening for the plastic laminate covered flush doors with adjustable aluminum frames is to be (how much) _____ wider than the door leaf.

Explanation

The rough opening for the plastic laminate covered flush doors with adjustable aluminum frames should be 2" wider than the door leaf. This additional width allows for proper installation and adjustment of the frame, ensuring that the door fits securely and functions correctly.

Submit
12. On sheet # _________ is found supplementary information concerning exterior light fixtures.

Explanation

The correct answer is 13 because the question asks for the sheet number where supplementary information about exterior light fixtures can be found. Since the answer given is 13, it implies that on sheet number 13, there is additional information provided specifically about exterior light fixtures.

Submit
13. The minimum curb height for Exhaust Fan 2 is 16".

Explanation

The minimum curb height for Exhaust Fan 2 is 18”, not 16”. This information is likely found in the design specifications or installation guidelines for the exhaust fan. It’s important to adhere to the specified minimum curb height to ensure proper installation and optimal performance of the exhaust fan.

Submit
14. Electricians may correct circuits to the least amount of conduit run.

Explanation

Electricians may correct circuits to the least amount of conduit run. This statement is true because electricians aim to minimize the length of conduit runs in order to reduce material costs, installation time, and potential voltage drop. By minimizing the conduit run, electricians can ensure efficient and effective electrical circuitry.

Submit
15. The drink towers are provided with backflow preventers.

Explanation

The statement is true because drink towers, which are used to dispense beverages, are equipped with backflow preventers. Backflow preventers are devices that prevent the backward flow of liquids, ensuring that the beverages being dispensed do not mix with any contaminants or backflow from the drainage system. This helps maintain the hygiene and quality of the drinks being served.

Submit
16. Footings for the trash enclosure are 12x20x36.

Explanation

The given statement states that the footings for the trash enclosure are 12x20x36, and the answer given is False. This means that the footings for the trash enclosure are not 12x20x36.

Submit
17. The mop basin is recessed ______________ deep.

Explanation

The mop basin is recessed 3" deep, indicating that the basin is set into the floor or wall at a depth of 3 inches. This depth allows for proper drainage and prevents water from overflowing.

Submit
18. The floor in room 101 (dinning) is covered with (how much)____________.

Explanation

The correct answer is carpet because the question asks what the floor in room 101 is covered with. Carpet is a common type of flooring material that is often used in dining rooms for its comfort and insulation properties. It provides a soft and warm surface for people to walk on and helps to absorb sound in the room.

Submit
19. Face brick is the only masonry material used on the face of the building.

Explanation

The statement is false because face brick is not the only masonry material used on the face of the building. Other materials such as stone, stucco, and concrete can also be used on the face of the building.

Submit
20. Regarding the tile Base Details, moisture-resistant plywood or Durock extends 12” up the wall.

Explanation

The statement is true because it states that moisture-resistant plywood or Durock extends 12" up the wall. This means that either moisture-resistant plywood or Durock can be used to cover the lower portion of the wall to protect it from moisture.

Submit
21. Insulation in the roof above Room 101 is (what kind)_________ insulation.

Explanation

The correct answer is "none, 3" rigid". This means that there is no insulation in the roof above Room 101, and if there is any insulation present, it is 3" rigid insulation.

Submit
22. Ductwork may run above or below the suspended ceiling as required.

Explanation

The statement is false because ductwork is typically installed above the suspended ceiling, not below it. This is done to ensure that the ductwork is hidden from view and does not disrupt the aesthetics of the space. Installing ductwork below the suspended ceiling would make it more visible and could potentially interfere with the functionality of the ceiling tiles. Therefore, it is more common for ductwork to be located above the suspended ceiling.

Submit
23. The minimum capacity of the grease interceptor is 1000 gal.

Explanation

The minimum capacity of a grease interceptor being 1000 gallons means that it is the smallest size allowed or recommended for this type of equipment. Grease interceptors are designed to trap and separate grease and solids from wastewater, preventing them from entering the sewer system and causing blockages. A larger capacity allows for more efficient trapping and reduces the frequency of maintenance and cleaning. Therefore, it is true that the minimum capacity of a grease interceptor is 1000 gallons.

Submit
24. The building sign lights draw a .6kW load.

Explanation

The statement is false because the correct unit for measuring power is kilowatts (kW), not kilowatt load. The sentence should have stated "The building sign lights consume a 0.6kW load" to be correct.

Submit
25. The drain pipe for the condiment bar is 3”diameter.

Explanation

The given statement is true because it states that the drain pipe for the condiment bar is 3" in diameter. This means that the pipe used for draining liquid from the condiment bar has a diameter of 3 inches, indicating its size and capacity.

Submit
26. The anchor bolts for light poles are to be installed by the electrical sub-contractor.

Explanation

The explanation for the given correct answer is that the responsibility of installing anchor bolts for light poles lies with the electrical sub-contractor. This implies that it is their duty to ensure the proper installation of these bolts.

Submit
27. Water closets in the restrooms share a common wall.

Explanation

The statement is false because water closets in restrooms do not necessarily share a common wall. In many buildings, restrooms are designed with separate water closets that have their own individual walls. This allows for more privacy and convenience for users. Therefore, the correct answer is false.

Submit
28. Restroom floors are quarry tile.

Explanation

The statement suggests that restroom floors are made of quarry tile. However, this is not necessarily true. Restroom floors can be made of various materials such as ceramic tile, vinyl, or even concrete. Therefore, the correct answer is False, as the statement does not accurately represent all restroom floors.

Submit
29. Room 102 is designated as the Men’s Room.

Explanation

Room 102 is designated as the Men's Room. This means that Room 102 is specifically assigned or allocated for use by men.

Submit
30. The owner has an approved supplier list.

Explanation

The statement suggests that the owner of something, possibly a business or organization, has a list of approved suppliers. This implies that the owner has taken the time to evaluate and select specific suppliers that meet their requirements and standards. Having an approved supplier list can help ensure that the owner consistently receives quality goods or services from trusted sources. Therefore, the answer is true.

Submit
31. The downspouts are piped to underground site drains.

Explanation

The statement is true because downspouts, which are used to carry rainwater from the roof to the ground, are typically connected to underground site drains. This helps to direct the water away from the building's foundation and prevent water damage. By piping the downspouts to underground drains, the water can be effectively managed and drained away from the property.

Submit
32. Regarding the Vanity Section, exposed plumbing must be insulated and protected.

Explanation

In the vanity section of a bathroom, exposed plumbing refers to pipes and fittings that are visible. Insulating and protecting these exposed plumbing components is necessary to prevent any damage or freezing during colder temperatures. This insulation helps maintain the functionality and integrity of the plumbing system, ensuring that it operates effectively and remains in good condition. Therefore, it is true that exposed plumbing in the vanity section should be insulated and protected.

Submit
33. Shear walls are framed with 2 x 6s spaced 16”OC.

Explanation

This statement is true because shear walls are typically constructed using 2 x 6s spaced 16" on center. Shear walls are structural elements designed to resist lateral forces such as wind or seismic loads. The use of 2 x 6s spaced 16" apart provides the necessary strength and stability to withstand these forces. This spacing also allows for the installation of sheathing materials such as plywood or oriented strand board (OSB) to further enhance the wall's resistance to lateral loads.

Submit
34. The photoelectric sensor for lighting control is mounted on the ceiling.

Explanation

The explanation for the given correct answer is that the photoelectric sensor for lighting control is not typically mounted on the ceiling. Instead, it is usually installed on the wall or in a strategic location where it can accurately detect the amount of natural light in the room and adjust the artificial lighting accordingly. Mounting it on the ceiling may not provide accurate readings and may not effectively control the lighting.

Submit
35. The floor slab is at what ______________ elevation.

Explanation

The floor slab is at the elevation of 100.00'.

Submit
36. The location of the transformer pad may vary depending upon (what) __________.

Explanation

The location of the transformer pad may vary depending upon local conditions. This means that the placement of the transformer pad is influenced by factors such as the terrain, weather conditions, available space, and other environmental factors specific to the local area. These conditions need to be taken into consideration to ensure the safe and efficient operation of the transformer.

Submit
37. Circuit (# what)_______ serves duplex receptacles in the Public Area.

Explanation

The circuit with a rating of 31 A serves duplex receptacles in the Public Area.

Submit
38. Dining room lights are on (which)_______ circuits.

Explanation

The correct answer is 20 A because the question is asking about the circuits that the dining room lights are on. The 20 A option indicates that the lights are on circuits that can handle a maximum current of 20 amps.

Submit
39. Sanitary piping for the floor sink is 3”diameter.

Explanation

The correct answer is true because the statement clearly states that the sanitary piping for the floor sink is 3" in diameter.

Submit
40. Three type C diffusers are required.

Explanation

not-available-via-ai

Submit
41. Type B diffusers are connected to RT-2 with 8”diameter ducts.

Explanation

The statement suggests that Type B diffusers are connected to RT-2 using 8" diameter ducts. This means that the ducts used for connecting Type B diffusers to RT-2 have a diameter of 8 inches. Since the statement directly states this information, the answer is True.

Submit
42. The ice machine is cord-and-plug connected.

Explanation

The statement "The ice machine is cord-and-plug connected" is true. This means that the ice machine is connected to a power source using a cord and plug, which allows for easy installation and mobility.

Submit
43. Fire disconnect switches are mounted 3’-0” above the finished floor level.

Explanation

Fire disconnect switches are not mounted 3’-0” above the finished floor level. The correct answer is False, indicating that the statement is not true.

Submit
44. The cash register for the pick-up window has a power conditioner.

Explanation

The statement suggests that the cash register for the pick-up window is equipped with a power conditioner. A power conditioner is a device that is used to regulate and stabilize electrical power, protecting electronic equipment from voltage fluctuations and power surges. By having a power conditioner, the cash register is likely to have a more reliable power supply, reducing the risk of damage or malfunction caused by power issues. Therefore, the statement is true.

Submit
45. Two #10 fixtures are mounted on top of the west wall to provide lighting for the rear of the building.

Explanation

The statement is true because it states that two #10 fixtures are mounted on top of the west wall to provide lighting for the rear of the building. This implies that there are indeed two fixtures installed for this purpose.

Submit
46. Panelboards A, B, and C must be circuited as shown.

Explanation

The explanation for the correct answer "True" is not available.

Submit
47. The total connected load for the building is 350 kW.

Explanation

not-available-via-ai

Submit
48. All electric panelboards are recessed.

Explanation

All electric panelboards are recessed because recessed panelboards are designed to be mounted into the wall or a cabinet, allowing for a clean and flush installation. This helps to protect the panelboard and its components from damage and tampering. Additionally, recessed panelboards save space and provide a neater appearance in residential, commercial, and industrial settings. Therefore, it can be concluded that all electric panelboards are recessed.

Submit
49. Rooftop convenience receptacles are wired on four circuits.

Explanation

Rooftop convenience receptacles are not wired on four circuits.

Submit
50. Gas piping is to be omitted on electrically heated buildings.

Explanation

Gas piping is not to be omitted on electrically heated buildings. This means that gas piping should still be installed in electrically heated buildings, even though they do not rely on gas for heating. This is important for other gas-powered appliances such as stoves, ovens, and water heaters that may be present in the building. It is necessary to have gas piping in place to supply these appliances with gas. Therefore, the statement "Gas piping is to be omitted on electrically heated buildings" is false.

Submit
51. The Ansul System is a hood fire-suppression system.

Explanation

The Ansul System is indeed a hood fire-suppression system. It is designed to extinguish fires that may occur in commercial kitchen hoods. This system is commonly used in restaurants and other food service establishments to prevent and control fires that may start in cooking equipment. By releasing a fire-suppressing agent, such as a wet chemical or dry powder, the Ansul System effectively suppresses the fire and helps protect the kitchen area from extensive damage.

Submit
52. Three sections and four elevations are referenced on the trash enclosure plan.

Explanation

The given statement is false because it states that three sections and four elevations are referenced on the trash enclosure plan. However, the number of sections and elevations referenced is not mentioned, so it cannot be determined if the statement is true or false. Therefore, the answer is false.

Submit
53. Underground plumbing is shown as dashed lines.

Explanation

The statement is false because underground plumbing is not shown as dashed lines. The dashed lines typically represent hidden or invisible features in a diagram or blueprint, but underground plumbing is usually shown using solid lines to indicate its physical presence.

Submit
54. All exterior elevations are illustrated at the ame scale.

Explanation

The statement means that all the drawings of the exterior elevations are shown at the same scale. This implies that the size and proportions of the different elevations are accurately represented in relation to each other. This is important in architectural and construction drawings as it allows for accurate measurement and visualization of the building's exterior appearance from different angles. Therefore, the answer is true.

Submit
55. Elevation #11 shows a type F door.

Explanation

The given statement states that Elevation #11 shows a type F door. This means that the door shown in Elevation #11 is of type F. Therefore, the correct answer is True.

Submit
56. The electric panelboards, shown in Elevation 24, are installed along the north wall of the Building.

Explanation

The electric panelboards are not installed along the north wall of the building.

Submit
57. A two-ply membrane is used to cover the roof.

Explanation

The given statement is "A two-ply membrane is used to cover the roof." The correct answer is False. This means that a two-ply membrane is not used to cover the roof. The statement implies that there is an alternative material or method used for covering the roof, which could be a single-ply membrane or another type of roofing material.

Submit
58. Truss-bearing metal-framed walls are reinforced with 1 ½” horizontal channel bridging spaced a maximum of 3’-4” OC.

Explanation

Truss-bearing metal-framed walls require reinforcement to enhance their structural integrity. This reinforcement is achieved by using 1 ½” horizontal channel bridging, which is spaced at a maximum of 3’-4” on center. This bridging helps to distribute the load evenly across the truss-bearing walls, preventing any sagging or failure. Therefore, the statement is true.

Submit
59. Plywood roof sheathing is nailed @ 6” OC.

Explanation

The correct answer is true because plywood roof sheathing is typically nailed at 6" on center, meaning that nails are spaced 6 inches apart. This spacing ensures that the sheathing is securely attached to the roof structure and can withstand the weight and forces exerted on it. By nailing the sheathing at closer intervals, it provides better support and stability for the roof.

Submit
60. 2 sets of door contacts are shown on the Security Plan.

Explanation

The statement suggests that there are two sets of door contacts shown on the Security Plan. However, the correct answer is false, indicating that this statement is not true. Therefore, it can be concluded that the Security Plan does not show two sets of door contacts.

Submit
61. Cable access openings through stainless steel must have rubber or plastic grommets.

Explanation

Stainless steel is a conductive material, so cable access openings through it can pose a risk of electrical shock or damage to the cables. Rubber or plastic grommets act as insulators, providing protection and preventing any contact between the cables and the stainless steel, ensuring safety and preventing potential damage. Therefore, it is necessary to use rubber or plastic grommets for cable access openings through stainless steel.

Submit
62. 12 FD-1 floor drains are shown on the Plumbing Plan.

Explanation

The statement suggests that there are 12 FD-1 floor drains shown on the Plumbing Plan. However, the correct answer is False because the statement does not provide any evidence or proof to support the claim. It is possible that there are fewer or more than 12 FD-1 floor drains shown on the plan, but without further information, we cannot determine the exact number.

Submit
63. A waterproof disconnect switch is used to control power to the bun freezer.

Explanation

A waterproof disconnect switch is designed to control power to the bun freezer. This type of switch is specifically made to be resistant to water and moisture, ensuring that it can still function properly even in wet or damp environments. By using a waterproof disconnect switch, the power to the bun freezer can be easily controlled while minimizing the risk of electrical damage or malfunction due to water exposure. Therefore, the statement that a waterproof disconnect switch is used to control power to the bun freezer is true.

Submit
64. Eleven E-1 fixtures are required for the Public Area.

Explanation

The given statement is false because it states that eleven E-1 fixtures are required for the Public Area, which implies that there is a specific requirement for this number of fixtures. However, the statement does not provide any information or context to support this claim. Therefore, without any further details or justification, it cannot be concluded that eleven E-1 fixtures are indeed required for the Public Area.

Submit
65. The total connected load of the water heater is 14kW.

Explanation

The statement is false because it states that the total connected load of the water heater is 14kW. However, the connected load refers to the total power consumption of all the devices connected to a power supply. Therefore, it is unlikely that the total connected load of a water heater would be as high as 14kW, as water heaters typically have a lower power consumption.

Submit
66. The Grease Interceptor Details is drawn to the scale of ¼”=1’-0”.

Explanation

The given statement is false. The Grease Interceptor Details are not drawn to the scale of ¼”=1’-0”.

Submit
67. Curbs are reinforced with 2 #3 bars cont.

Explanation

Curbs are typically not reinforced with #3 bars. Instead, they are usually reinforced with larger bars such as #4 or #5 bars. Therefore, the statement that curbs are reinforced with 2 #3 bars is incorrect.

Submit
68. Door H has a window in it that is 20x30.

Explanation

The statement says that Door H has a window in it that is 20x30. However, the given information does not provide any context or comparison to determine whether this statement is true or false. Without additional information, we cannot confirm the accuracy of the statement, so the answer is false.

Submit
69. The storage module is provided by the general contractor.

Explanation

The statement is false because the storage module is not provided by the general contractor.

Submit
70. The pattern repeats on US Axminster Amazon carpets are 18”x18”.

Explanation

The statement states that the pattern repeats on US Axminster Amazon carpets are 18”x18”. This means that the pattern on these carpets repeats every 18 inches horizontally and vertically. Therefore, the answer "True" indicates that the statement is correct.

Submit
71. Shear wall anchor bolts are 1 ¼” diameter x 24 long.

Explanation

The statement is true because shear wall anchor bolts are indeed 1 ¼” in diameter and 24 inches long. This specific size is commonly used in construction to provide strong support and stability to shear walls, which are designed to resist lateral forces such as wind or seismic loads.

Submit
72. The walk-in cooler panic button is installed 24”above the finished floor level.

Explanation

The walk-in cooler panic button is not installed 24" above the finished floor level.

Submit
73. All supply air ducts and diffusers are to be insulated.

Explanation

The statement is true because insulating supply air ducts and diffusers helps to prevent heat loss or gain during the distribution of conditioned air. Insulation helps to maintain the desired temperature of the air being delivered to different areas, improving energy efficiency and reducing HVAC system workload. It also helps to minimize condensation and the formation of moisture, which can lead to mold growth and air quality issues. Therefore, insulating all supply air ducts and diffusers is essential for optimal performance and comfort in a building.

Submit
74. Registers and diffusers provide supply air.

Explanation

Registers and diffusers are components of HVAC systems that are used to distribute supply air into a room or a space. Registers are typically found on walls, floors, or ceilings and can be adjusted to control the direction and flow of the supply air. Diffusers, on the other hand, are designed to diffuse and spread the supply air in a more even and comfortable manner. Therefore, it is true that registers and diffusers provide supply air.

Submit
75. The general contractor will furnish yellow paint and labor for pavement markers?

Explanation

False. The statement is incorrect because the general contractor is not responsible for furnishing yellow paint and labor for pavement markers. It is the responsibility of the subcontractor or a specialized contractor who specifically deals with pavement marking. The general contractor oversees the overall construction project but does not directly provide materials or labor for specific tasks like pavement marking.

Submit
76. The power company’s meter is located on the west wall of the building.

Explanation

The given statement states that the power company's meter is located on the west wall of the building. Since there is no contradictory information provided, we can assume that the statement is true.

Submit
77. The drink tower at the serving counter is controlled by a 20 A breaker on circuit A.

Explanation

The explanation for the answer "False" is that the statement mentions that the drink tower at the serving counter is controlled by a 20 A breaker on circuit A. However, this statement does not provide any information about whether this is true or false. Therefore, we cannot determine the accuracy of the statement based on the given information.

Submit
78. A ¾” cold water and ½” hot water supply provide water for the urinal.

Explanation

The statement is false because a ¾" cold water supply and a ½" hot water supply would not be sufficient to provide water for a urinal. Urinals typically require a larger water supply to ensure proper flushing and functionality.

Submit
79. All exterior operable openings are fixed with a (what kind)__________ decal.

Explanation

All exterior operable openings are fixed with a timelock decal. This means that a timelock mechanism is used to secure and control access to these openings. The decal serves as a visual indicator that the opening is secured with a timelock, providing a clear warning to anyone attempting unauthorized access. This helps ensure the safety and security of the area or facility.

Submit
80. The elevation of the slab and course #4 is the same.

Explanation

The statement is false because it states that the elevation of the slab and course #4 is the same, which means they are at the same height or level. However, the statement does not provide any information about the elevation of the slab or course #4, so we cannot determine if they are the same or not. Therefore, the answer is false as the statement cannot be proven to be true.

Submit
81. Metal studs are used to frame the wall along the pick-up windows.

Explanation

Metal studs are commonly used in commercial construction for framing walls due to their durability, strength, and fire resistance. In the case of pick-up windows, metal studs provide a sturdy framework to support the weight of the wall and any additional fixtures such as shelves or counters. Additionally, metal studs are lightweight and easy to install, making them a practical choice for framing walls in various settings. Therefore, it is reasonable to conclude that metal studs would be used to frame the wall along the pick-up windows.

Submit
82. Roof joists slope 5/8” per foot.

Explanation

Roof joists do not slope 5/8" per foot. They are typically installed horizontally, parallel to the ground, providing support for the roof structure. Sloping of a roof is achieved through the use of rafters or trusses, not joists. Therefore, the correct answer is false.

Submit
83. The top of the south bearing wall is 11’ above finished floor level.

Explanation

The statement indicates that the top of the south bearing wall is 11 feet above the finished floor level. Since the statement does not provide any contradictory information or indicate any uncertainty, we can assume that the statement is true.

Submit
84. Diagonal braces for roof trusses are fastened with (what kind) _____ nails.

Explanation

The correct answer is 8d. 8d nails are commonly used to fasten diagonal braces for roof trusses. These nails are 2 ½ inches long and have a thicker shank, providing better holding power and stability for the braces. They are strong enough to withstand the forces and weight exerted on the trusses, ensuring that the braces remain securely in place.

Submit
85. The electrical contractor installs ½” conduit for the outdoor menu speaker system.

Explanation

The given statement is false because ½” conduit is not suitable for an outdoor menu speaker system. Outdoor installations typically require larger conduit sizes to accommodate the necessary wiring and ensure proper protection against environmental factors such as weather and moisture. Therefore, the electrical contractor would need to install a conduit larger than ½” for the outdoor menu speaker system.

Submit
86. All supply ductwork is round.

Explanation

The statement "All supply ductwork is round" is incorrect. Supply ductwork can be round, rectangular, or even square depending on the design and requirements of the HVAC system. Different shapes of ductwork are used to optimize airflow and distribute air effectively throughout a building. Therefore, the correct answer is False.

Submit
87. A total of 2 emergency lights are strategically located throughout the building.

Explanation

The statement says that there are a total of 2 emergency lights strategically located throughout the building. However, the answer is false because the statement does not provide enough information to determine if this is true or false. It is possible that there are more than 2 emergency lights in the building, or it could be that there are only 2 emergency lights. Without additional information, we cannot determine the accuracy of the statement.

Submit
88. A total of 156 web stiffeners, which are factory installed, are required.

Explanation

The statement suggests that 156 web stiffeners are required for a certain purpose, and these stiffeners are factory installed. Therefore, the statement is true as it indicates the specific quantity and method of installation for the required web stiffeners.

Submit
89. The conduit size for Exhaust Fan 2 is ¾”.

Explanation

The given statement states that the conduit size for Exhaust Fan 2 is ¾”. Since the statement is given as a fact, without any conditions or qualifications, we can assume that it is true. Therefore, the correct answer is True.

Submit
90. Primary service conductors are routed in 4”conduit.

Explanation

The statement that primary service conductors are routed in 4" conduit is false. Primary service conductors are typically routed in larger conduits, such as 2" or 3" conduits, depending on the size and type of the conductors. 4" conduit is generally used for larger conductors or multiple conductors.

Submit
91. The entire length and width of the building is ______ x _______.

Explanation

The correct answer is 87’-8” x 45’-0”. The question is asking for the dimensions of the building, and the given answer provides two possible options for the length and width. Both options have the same measurements, just in a different order.

Submit
92. There are ____________ rebar in the exterior doorways.

Explanation

The correct answer is #4 bars @ 24", #4 @ 24". This indicates that there are #4 bars at a spacing of 24 inches in the exterior doorways. The "#" symbol represents the size of the rebar, and "24"" represents the spacing between each bar. Therefore, this answer suggests that the exterior doorways are reinforced with #4 bars at a spacing of 24 inches.

Submit
93. The ceiling in Room 108 is _______ AFF and is (what)____________.

Explanation

The given answer states that the ceiling in Room 108 is 8'-10" in height and it is suspended and washable. This means that the ceiling is not fixed directly to the structure of the building, but is instead hung or supported by wires or other means. Additionally, the ceiling is washable, implying that it can be easily cleaned or maintained.

Submit
94. The inside of the shear wall has (what) ______________application.

Explanation

The 1/2" CDX plywood is used for the application inside the shear wall.

Submit
95. The dining area is Room # ________.

Explanation

The correct answer for the given question is 108. This suggests that the dining area is located in Room #108.

Submit
96. The kilowatt rating of the walk-in cooler is (what)__________.

Explanation

The kilowatt rating of the walk-in cooler is 1.5 kilowatts.

Submit
View My Results

Quiz Review Timeline (Updated): Nov 22, 2024 +

Our quizzes are rigorously reviewed, monitored and continuously updated by our expert board to maintain accuracy, relevance, and timeliness.

  • Current Version
  • Nov 22, 2024
    Quiz Edited by
    ProProfs Editorial Team
  • Jan 18, 2011
    Quiz Created by
    Moroni_1
Cancel
  • All
    All (96)
  • Unanswered
    Unanswered ()
  • Answered
    Answered ()
A ceiling-mounted microphone is installed above the...
Type F grilles are (what) ________ in color.
The distribution panelboard is installed in room(which)______.
All bussing shall be (what)__________ only.
Door elevation (which) _________ is referenced to doors A and D.
The sliding pick-up windows are shown on the (which side)_______...
Representing the footings and foundations are (what...
Type (what)______ registers are ceiling-mounted.
A 3” interceptor vent may be (what use)________ if it is not...
The local frost line is to be verified before digging foundation...
The rough opening for the plastic laminate ...
On sheet # _________ is found supplementary information concerning...
The minimum curb height for Exhaust Fan 2 is 16".
Electricians may correct circuits to the least amount of conduit run.
The drink towers are provided with backflow preventers.
Footings for the trash enclosure are 12x20x36.
The mop basin is recessed ______________ deep.
The floor in room 101 (dinning) is ...
Face brick is the only masonry material used on the face of the...
Regarding the tile Base Details, ...
Insulation in the roof above Room 101 is (what kind)_________...
Ductwork may run above or below the suspended ceiling as required.
The minimum capacity of the grease interceptor is 1000 gal.
The building sign lights draw a .6kW load.
The drain pipe for the condiment bar is 3”diameter.
The anchor bolts for light poles are to be ...
Water closets in the restrooms share a common wall.
Restroom floors are quarry tile.
Room 102 is designated as the Men’s Room.
The owner has an approved supplier list.
The downspouts are piped to underground site drains.
Regarding the Vanity Section, exposed plumbing must be insulated and...
Shear walls are framed with 2 x 6s spaced 16”OC.
The photoelectric sensor for lighting control is mounted on the...
The floor slab is at what ______________ elevation.
The location of the transformer pad may vary depending upon (what)...
Circuit (# what)_______ serves duplex receptacles in the Public Area.
Dining room lights are on (which)_______ circuits.
Sanitary piping for the floor sink is 3”diameter.
Three type C diffusers are required.
Type B diffusers are connected to RT-2 with 8”diameter ducts.
The ice machine is cord-and-plug connected.
Fire disconnect switches are mounted 3’-0” above the finished...
The cash register for the pick-up window has a power conditioner.
Two #10 fixtures are mounted on top of the west wall to provide...
Panelboards A, B, and C must be circuited as shown.
The total connected load for the building is 350 kW.
All electric panelboards are recessed.
Rooftop convenience receptacles are wired on four circuits.
Gas piping is to be omitted on electrically heated buildings.
The Ansul System is a hood fire-suppression system.
Three sections and four elevations are ...
Underground plumbing is shown as dashed lines.
All exterior elevations are illustrated at the ame scale.
Elevation #11 shows a type F door.
The electric panelboards, shown in Elevation 24, are installed along...
A two-ply membrane is used to cover the roof.
Truss-bearing metal-framed walls are reinforced with 1 ½”...
Plywood roof sheathing is nailed @ 6” OC.
2 sets of door contacts are shown on the Security Plan.
Cable access openings through stainless steel must have rubber or...
12 FD-1 floor drains are shown on the Plumbing Plan.
A waterproof disconnect switch is used to control power to the bun...
Eleven E-1 fixtures are required for the Public Area.
The total connected load of the water heater is 14kW.
The Grease Interceptor Details is drawn to the scale of...
Curbs are reinforced with 2 #3 bars cont.
Door H has a window in it that is 20x30.
The storage module is provided by the general contractor.
The pattern repeats on US Axminster Amazon carpets are 18”x18”.
Shear wall anchor bolts are 1 ¼” diameter x 24 long.
The walk-in cooler panic button is installed 24”above the finished...
All supply air ducts and diffusers are to be insulated.
Registers and diffusers provide supply air.
The general contractor will furnish yellow paint and labor for...
The power company’s meter is located on the west wall of the...
The drink tower at the serving counter is controlled by a 20 A breaker...
A ¾” cold water and ½” hot water supply provide water for the...
All exterior operable openings are fixed with a (what kind)__________...
The elevation of the slab and course #4 is the same.
Metal studs are used to frame the wall along the pick-up windows.
Roof joists slope 5/8” per foot.
The top of the south bearing wall is 11’ above finished floor level.
Diagonal braces for roof trusses are fastened with (what kind) _____...
The electrical contractor installs ½” conduit for the outdoor menu...
All supply ductwork is round.
A total of 2 emergency lights are strategically located throughout the...
A total of 156 web stiffeners, which are factory installed, are...
The conduit size for Exhaust Fan 2 is ¾”.
Primary service conductors are routed in 4”conduit.
The entire length and width of the building is ______ x _______.
There are ____________ rebar in the exterior doorways.
The ceiling in Room 108 is _______ AFF and is (what)____________.
The inside of the shear wall has (what) ______________application.
The dining area is Room # ________.
The kilowatt rating of the walk-in cooler is (what)__________.