This Sterile Processing quiz assesses knowledge crucial for handling surgical instruments and maintaining a sterile environment in medical facilities. It covers decontamination, sterilization processes, and safety measures, essential for healthcare professionals to ensure patient safety and compliance with industry standards.
Receiving
Sorting
Soaking
Cleaning
Rate this question:
OSHA
Scrubs
PEE
PPE
Rate this question:
Two days before they will be used
The day or evening before they will be used
The morning of the planned surgery
Early morning(for morning procedures) and early day for (afternoon procedures) on the day for the surgery
Rate this question:
Neutral
Negative
Forced air
Positive
Rate this question:
Empolyability skills
Communication abilities
Safety practices
Faciliy system reponsibilities
Rate this question:
Most lilely to occur during international travel
Those which occur in the course of being treated in a hospital
Those without known cures
Caused by durg resistant organisms
Rate this question:
Job duty list
Job specification
Task summary review
Rate this question:
Prefix
Root
Suffix
Noun
Rate this question:
To repair
To open
To cut open
Examine
Rate this question:
Para
Peri
Parta
Pana
Rate this question:
CABG
BSO
ORIF
TAH
Rate this question:
Within the colon
Between the toes
Within the bladder
Beteen the ribs
Rate this question:
Prefix
Suffix
Root
Analog
Rate this question:
Smooth muscle
Cardiac muscle
Skeletal muscle
Fascia muscle
Rate this question:
Coccus
Bacillus
Anhydrous
Anerobic
Rate this question:
Coccus
Bacillus
Anhydrous
Anerobic
Rate this question:
APIC
EPA
DOT
FPA
Rate this question:
CDC
AAMI
APIC
AORN
Rate this question:
Class 1
Class 2
Class 3
Not regulated by FDA
Rate this question:
Transmission devices
Fomites
Carriers
Framiseals
Rate this question:
Water conductivity
Sanitization
Deionization
Sterilization
Rate this question:
Age, disease, nutritional status, aerobic organisms
Age, disease, nutritional status, anaerobic organisms
Age, disease, nutritional status, trauma
Age, disease, nutritional status, gender
Rate this question:
Repopulation
Binary fission
Replication
Bilateral reproduction
Rate this question:
Low PH
Hight PH
Neutral pH
It depends on the water temperature and exposure time
Rate this question:
Are fever-producing substances
Are microoganisms that have survived steriliztion
Cause CJD
Are soil particles
Rate this question:
Sterilization
Thermal disinfection
Hight-level
Mechanical disinfection
Rate this question:
Glutaraldehydes
Disinfectants
Halogens
Antiseptics
Rate this question:
Critial items
Semi-critial items
Non-critial items
Equipment
Rate this question:
High-level disinfection
Thermal disinfection
Sterilization
Chemical disinfection
Rate this question:
Halogens
Quaternary ammonium compounds
Alcohol
Phenolics
Rate this question:
Intermediate to low-level disinfectant
Intermediate to high-level disinfectant
High-level disinfectant
Sterilants
Rate this question:
Glutaraldehyde and OPA
Glutaraldehyde and phenolics
Halogens and OPA
Quateray ammonium compounds and phenolics
Rate this question:
Heated chemicals
Heated glurataldehyde
Prolonged high pressure steam
Heated water
Rate this question:
3 min
5 min
10 min
20 min
Rate this question:
Phenolics
Chlorine
Iodophors
OPA
Rate this question:
1 to 1 1/2
1 1/2 to 2
2 to 2 1/2
2 1/2 to 3
Rate this question:
Laser-etching
Acid-base etching
Elctric etching (engraving)
Heat-fused nylon
Rate this question:
Unclog the suction during surgery
Clean the suction in the decontamination area
Faciliate the sterilation process
Provide a measuring guide for the surgeon
Rate this question:
Tissue paper
A plastic dowel rod
Rubber testing material
An index card
Rate this question:
Black handles
Silver handles
Gold handles
The letters "TC"
Rate this question:
Check the collar at the distal tip
Try to slide the insulation back
Check the handle for chipping or cracking
Visually check the instument's shaft
Rate this question:
High-level disinfecting/sterillzing
Leak-testing
Manual cleaning
Drying
Rate this question:
Forced air
Water containing approved sterilant
A heated glutaraldehyde
Filered water
Rate this question:
To keep fluid from entering the unit
To keep functioning batteries and cords clean
To prevent electrical shock
An automatic endoscope reprocessor
Rate this question:
An ultrasonic cleaner
A washer-decontaminator
A flush-pulse endoscope reprocessor
An automatic endoscopes reprocessor
Rate this question:
Colonoscope
Sigmoidoscope
Gastroscopes
Ureteroscope
Rate this question:
Be decontaminated if they apper soiled upon arrival
Be sterillized useing a low temperature process
Be decontaminated before use
Not be used
Rate this question:
Not all endoscopes can be processed in an AER
Ultasonic cleaning is the process of choice for endoscopes
Flexible endoscopes are not easily damaged
All endoscopes should be steam sterilized
Rate this question:
Quiz Review Timeline (Updated): Jun 20, 2024 +
Our quizzes are rigorously reviewed, monitored and continuously updated by our expert board to maintain accuracy, relevance, and timeliness.
Wait!
Here's an interesting quiz for you.