Anesthesia machines quiz MCQ trivia! These machines are also called anesthesia workstations and borrow from the foundations made by Henry Boyle. These machines can induce sleep where a patient or animal will not feel any pain as they undergo surgical procedures. How good are you when it comes to using these machines on patients and solving some of the issues See morethey have?
This quiz not only serves as a robust learning tool but also as a benchmark for your existing knowledge, helping you identify areas for improvement. By participating in our "Anesthesia Machines Quiz," you embrace the opportunity to excel in your field, ensuring you are well-equipped to handle the anesthesia equipment with confidence and expertise.
Not significant
Leads to an artificially high reading
Leads to a damping of the tracing
Has the greatest effect on the mean blood pressure
Has a greater effect on the mean blood pressure
Rate this question:
Fail-safe valve
O2 analyzer
Gas rotamers
Disconnection alarm
Diameter index safety system
Rate this question:
Air bubbles between the catheter and transducer
A kink in the tubing between the catheter and the transducer
A blood clot within the catheter
Using soft tubing
All of the above
Rate this question:
Attachment of the wrong compression gas cylinder to the O2 yoke
Crossing the pipelines during daily set-up
Malfunctioning rotamer
Fresh gas line disconnection from the machine to the hospital supply
Disconnection of the O2 supply system from the patient
Rate this question:
Mapleson A
Mapleson B
Mapleson C
Mapleson D
Mapleson E
Bain Circuit
Rate this question:
Disconnect the ET tube
Extubate the patient
Cover the area with water
Use the fire extinguisher
Rate this question:
Mapleson A
Mapleson B
Mapleson C
Mapleson D
Mapleson E
Bain Modification
Rate this question:
Air : Yellow
Oxygen : Green
Carbon Dioxide : Orange
Nitrous Oxide : Blue
Nitrogen : Black
Rate this question:
2200, 2200, 2200
2200, 1100, 550
745, 745, 745
745, 373, 187
Rate this question:
36 minutes
42 minutes
58 minutes
67 minutes
> 75 minutes
Rate this question:
118 / 60
130 / 72
142 / 84
142 / 72
130 / 84
Rate this question:
CaCO3 + H2O
NaHCO3 + H2O
NaCO3 + H2O
None of the above
Rate this question:
3, 4, 2, 1, 5
4, 3, 5, 2, 1
4, 3, 5, 2, 1
3, 4, 5, 2, 1
Rate this question:
Test scavenging system function
Verify that there are no leaks in the gas supply lines between the flowmeters and the common gas outlet
Verify that patient suction is adequate to clear the airway
Calibrate the oxygen monitor and check the low oxygen alarm
Rate this question:
None of the above
Percent sevoflurane delivered will increase, partial pressure of sevoflurane will also increase
Percent sevoflurane delivered will increase, partial pressure of sevoflurane will remain the same
Percent sevoflurane delivered will remain the same, partial pressure of sevoflurane will also remain the same
Percent sevoflurane delivered will decrease, and partial pressure of sevoflurane will also decrease
Rate this question:
Hypoxia
Barotrauma
Hypoventilation
Hyperventilation
A low-circuit pressure signal
Rate this question:
Incompetent inspiratory valve
Incompetent expiratory valve
Incompetent pop off valve
Breathing circuit air leak
Exhausted CO2 absorbent
More than one of the above
More than two of the above
None of the above
Rate this question:
Quiz Review Timeline (Updated): Apr 10, 2024 +
Our quizzes are rigorously reviewed, monitored and continuously updated by our expert board to maintain accuracy, relevance, and timeliness.