1. The "ideal" instrument-processing area should include all of the following, except?

Submit
Please wait...
About This Quiz
Old -hltinf002 Process Reusable Instruments - Quiz

.

2.

What first name or nickname would you like us to use?

You may optionally provide this to label your report, leaderboard, or certificate.

2. According to the ADA Guidelines, "When manual cleaning of instruments, ________________ tap water is suitable?"

Submit

3. True or false?The sterilisation area workflow pattern flows from the clean area towards the contamination area.

Submit

4. Tick the following items found in the contaminated area of a sterilisation processing area.

Submit

5. The monitoring test used to determine whether the ultrasonic cleaner is working properly, is known as the _______________________?

Submit

6. True or false?Packaging wraps are not to be reused

Submit

7. The purpose of surface disinfection includes all of the following, except?

Submit

8. An Australian regulatory agency that creates the infection control standards that we must follow is?

Submit

9. According to the ADA Guidelines, "Items must be free of _______________ soil before being placed in an ultrasonic cleaner?"

Submit

10. True or false?Precleaning before disinfection is not recommended.

Submit

11. True or false?You must ware appropriate PPE while cleaning and disinfection environmental surfaces.

Submit

12. True or false?Disinfection is the same as sterilisation.

Submit

13. According to The Guidelines, 'ONLY those chemical disinfectants that are ___________ with the Therapeutic Goods Association (TGA) may be used.' p.80

Submit

14. According to the ADA Guidelines, "As residual moisture may impede the sterilisation process, instruments to be sterilised by steam should be dried."  Suitable methods include all of the following, except?

Submit

15. According to the ADA, what is the sterilistation cycle for hollow objects where the ratio of the length of the hollow portion to its diameter is more than 1:5?

Submit

16. A thermal disinfection machine________?

Submit

17. It is recommend that instruments are dried before they are wrapped or bagged for the steam steriliser.

Submit

18. According to the ADA Guidelines, "A package is considered to be non-sterile" for all of the following, except?

Submit

19. Steam sterilisers sterilise dental instruments and other items by means of ____________?

Submit

20. The following are recommendation for properly loading a steam steriliser, except?

Submit

21. If a package is damaged after the sterilisation process, it may be used?

Submit

22. The monitoring test that involves the use of a heat-sensitive chemical that changes colour when exposed to certain conditions, is known as the _______________________?

Submit

23. The monitoring test that is the only approved way to confirm if sterilisation has occurred, is known as the _______________________?

Submit

24. The monitoring test that measures the effectiveness of the air removal and even penetration of steam in a pre-vacuum steriliser, is known as the _______________________?

Submit

25. You must follow manufacturers recommendation on which disinfectants to use on dental equipment

Submit

26. Biologic monitoring, or spore testing is recommend to be completed at least __________?

Submit

27. Which type of chemical disinfectant is also known as household bleach?

Submit

28. According to the ADA Guidelines, the Bowie Dick Test is recommend to be completed at least __________?

Submit

29. According to the ADA Guidelines, "If an instrument cannot be cleaned it cannot be safely _______?"

Submit

30. Tick the following aseptic techniques used to reduce the spread of microorganisms:

Submit

31. A slime-producing bacterial communities that may also harbor fungi, algae, and protozoa is known as a __________?

Submit

32. True or false?No cleaning or disinfection is required within the dental laboratory or radiology area.

Submit

33. Match the words to complete the following sentences regarding the ADA Guidelines on "The Storage of processed instruments." 

Submit

34. Match the following classification of instruments with its definition

Submit

35. Match the words to complete the following sentences regarding the ADA Guidelines on "The Design of the reprocessing area." 

Submit
×
Saved
Thank you for your feedback!
View My Results
Cancel
  • All
    All (35)
  • Unanswered
    Unanswered ()
  • Answered
    Answered ()
The "ideal" instrument-processing area should include all of...
According to the ADA Guidelines, "When manual cleaning of...
True or false?The sterilisation area workflow pattern flows from...
Tick the following items found in the contaminated area of a...
The monitoring test used to determine whether the ultrasonic...
True or false?Packaging wraps are not to be reused
The purpose of surface disinfection includes all of the following,...
An Australian regulatory agency that creates the infection control...
According to the ADA Guidelines, "Items must be free of...
True or false?Precleaning before disinfection is not recommended.
True or false?You must ware appropriate PPE while cleaning and...
True or false?Disinfection is the same as sterilisation.
According to The Guidelines, 'ONLY those chemical disinfectants that...
According to the ADA Guidelines, "As residual moisture may impede...
According to the ADA, what is the sterilistation cycle for hollow...
A thermal disinfection machine________?
It is recommend that instruments are dried before they are wrapped or...
According to the ADA Guidelines, "A package is considered to be...
Steam sterilisers sterilise dental instruments and other items by...
The following are recommendation for properly loading a steam...
If a package is damaged after the sterilisation process, it may be...
The monitoring test that involves the use of a heat-sensitive...
The monitoring test that is the only approved way to confirm if...
The monitoring test that measures the effectiveness of the air removal...
You must follow manufacturers recommendation on which disinfectants to...
Biologic monitoring, or spore testing is recommend to be completed at...
Which type of chemical disinfectant is also known as household bleach?
According to the ADA Guidelines, the Bowie Dick Test is recommend to...
According to the ADA Guidelines, "If an instrument cannot be cleaned...
Tick the following aseptic techniques used to reduce the spread of...
A slime-producing bacterial communities that may also harbor fungi,...
True or false?No cleaning or disinfection is required within the...
Match the words to complete the following sentences regarding the ADA...
Match the following classification of instruments with its definition
Match the words to complete the following sentences regarding the ADA...
play-Mute sad happy unanswered_answer up-hover down-hover success oval cancel Check box square blue
Alert!