PTEC 132 - Exam - Chapter 12 - Symbols

41 Questions | Attempts: 141
Share

SettingsSettingsSettings
PTEC 132 - Exam - Chapter 12 - Symbols - Quiz

Questions and Answers
  • 1. 
    Using the Timtene Unit Drawing answer the following questions. What type of line connects T-101 and E 104?
    • A. 

      Mechanical link

    • B. 

      Capillary tubing

    • C. 

      Pneumatic line

    • D. 

      Major process line

  • 2. 
    What is the Number 50?
    • A. 

      Condenser - heat exchanger

    • B. 

      Spiral heat- exchanger

    • C. 

      Shell and tube heat exchanger

    • D. 

      Air cooled heat exchanger

  • 3. 
    What is Number 107?
    • A. 

      Pneumatic line

    • B. 

      Capillary tubing

    • C. 

      Future equipment

    • D. 

      Mechanical link

  • 4. 
    What is Number 36?
    • A. 

      Air cooled heat exchanger

    • B. 

      Rotary compressor and silencers

    • C. 

      Kettle reboiler

    • D. 

      Spiral heat exchange

  • 5. 
    What is Number 30?
    • A. 

      Motor circuit contacts

    • B. 

      Rotary compressor and silencers

    • C. 

      Gas turbine

    • D. 

      Spiral heat exchanger

  • 6. 
    What is Number 82?
    • A. 

      local recorder- remote location

    • B. 

      Level controller- remote location

    • C. 

      Level recorder- remote location

    • D. 

      Level remote controller

  • 7. 
    What is Number 41?
    • A. 

      Condenser - heat exchanger

    • B. 

      Spiral heat exchanger

    • C. 

      Shell and tube heat exchanger

    • D. 

      Air cooled heat exchanger

  • 8. 
    What is Number 117?
    • A. 

      Capillary tubing

    • B. 

      Software or data link

    • C. 

      Pneumatic line

    • D. 

      Mechanical link

  • 9. 
    What is Number 54?
    • A. 

      Forced draft, counter- flow, cooling tower

    • B. 

      Natural draft, hyperbolic, cooling tower

  • 10. 
    What is Number 25?
    • A. 

      Internal floating roof tank

    • B. 

      Dome roof tank

    • C. 

      Open top tank

    • D. 

      Double wall tank

  • 11. 
    What is Number 110?
    • A. 

      Recorder stand

    • B. 

      Recorder space

    • C. 

      Removable spool

    • D. 

      Removable stand

  • 12. 
    What is Number 205?
    • A. 

      Level indicating controller- PLC , remote location

    • B. 

      Level recording controller -remote location

    • C. 

      Level indicating controller- remote location

    • D. 

      Level transmitter- remote location

  • 13. 
    What is Number 153?
    • A. 

      In-line element

    • B. 

      In-line mixer

    • C. 

      Diverter valve

    • D. 

      Converter or transducer

  • 14. 
    What is Number 62?
    • A. 

      Maximum

    • B. 

      Motor

    • C. 

      Meter

    • D. 

      Motor circuit contacts

  • 15. 
    What is Number 26?
    • A. 

      Shell and tube heat exchanger - single pass

    • B. 

      Shell and tube heat exchanger -multi- pass

    • C. 

      Plate and frame heat exchanger

    • D. 

      Air cooled heat exchanger

  • 16. 
    What is Number 5?
    • A. 

      Centrifugal pump- horizontally mounted

    • B. 

      Screw pump

    • C. 

      Positive displacement pump

    • D. 

      Centrifugal pump- vertically mounted

  • 17. 
    What is Number 27?
    • A. 

      Shell and tube heat exchanger - single pass

    • B. 

      Shell and tube heat exchanger multi-pass

  • 18. 
    What is Number 101?
    • A. 

      Capillary tubing

    • B. 

      Future equipment

    • C. 

      Pneumatic line

    • D. 

      Mechanical link

  • 19. 
    What is Number 48?
    • A. 

      Natural draft, hyperbolic, cooling tower

    • B. 

      Packed column

    • C. 

      Mixing reactor

    • D. 

      Plate or tray distillation column

  • 20. 
    What is Number 143?
    • A. 

      Pressure reducing regulator

    • B. 

      Back pressure regulator

    • C. 

      Reverse valve positioner

    • D. 

      Forward valve positioner

  • 21. 
    What is Number 40?
    • A. 

      Condenser - heat exchanger

    • B. 

      Plate and frame heat exchanger

    • C. 

      Shell and tube heat exchanger

    • D. 

      Air cooled heat exchanger

  • 22. 
    What is Number 75?
    • A. 

      Pressure reducing regulator

    • B. 

      Back pressure regulator

    • C. 

      Reverse valve positioner

    • D. 

      Forward valve positioner

  • 23. 
    What is Number 106?
    • A. 

      Capillary tubing

    • B. 

      Future equipment

    • C. 

      Pneumatic line

    • D. 

      Mechanical link

  • 24. 
    What is Number 245?
    • A. 

      Flow element

    • B. 

      Flow controller

    • C. 

      Flow indicating controller - remote location

    • D. 

      Flow indicator

  • 25. 
    What is Number 104?
    • A. 

      Hydraulic line

    • B. 

      Capillary tubing

    • C. 

      Pneumatic line

    • D. 

      Mechanical link

Back to Top Back to top