Hornbill Industrial Training provides CompEx training and certification, including CompEx Gas/Vapour, Dust, Mechanical, Refresher, Responsible Persons and Foundation courses.
This is a Hornbill Industrial Training Mock CompEx Online Exam.
Ga, Gb, Gc
Gd, Ge, Gn
Gia, Gib, Gic
Gx, Gy, Gz
Rate this question:
Put at least one bolt back and hang a danger notice
Put at least half the bolts back and hang a danger notice
Put all bolts back spanner tight and check the flange gaps
Put no bolts back and leave it until the next inspection
Rate this question:
Ignition source
Fuel supply
Enclosure
Oxygen
Rate this question:
The equipment must be installed in a safe area
The equipment cannot be used outdoors
The equipment does not have an IP rating
Special conditions apply, refer to documentation
Rate this question:
5 full threads
8 full threads
3 full threads
10 full threads
Rate this question:
Oxygen
An Enclosure
Ignition source
Fuel
Rate this question:
The health and safety of workers
The electricity at work act
The design and trade of explosion protection equipment
Standardisation of electrical voltages
Rate this question:
Three fully engaged threads
Five fully engaged threads
Eight fully engaged threads
Ten fully engaged threads
Rate this question:
Twisting the strands
Soldering the strands
Fit coloured sleeving
Fit cable lugs or core-end sleeves
Rate this question:
Only evidence of having the necessary skills for the scope of work
Only evidence of having the necessary skills for the scope of work and competence across a range of activities
Evidence of having the necessary skills for the scope of work and competence across a range of activities and of relevant knowledge and understanding of protection types
Have HNC in Engineering
Rate this question:
Not likely to be present in normal operations
Not present during normal operations
Present continuously, or for long periods
Present in normal operations occasionally
Rate this question:
Manufacturers documentation
The basic requirements for working in zoned areas
Circuit Diagrams
How the equipment operates
Rate this question:
-10oC to +20oC
-20oC to +40oC
-30oC to +60oC
-40oC to +80oC
Rate this question:
Heavy equipment is mounted on piles
An ignition in one part of an enclosure causes higher explosion pressure in another part
There is a build up of pressure causing material fatigue
The gas pressure causes a vent to open
Rate this question:
Certified meeting the requirements on IEC60079-0
EX d Barrier Gland
Ex e Gland
Ex d Gland
Rate this question:
The equipment is unsuitable for any area
The equipment can only be used in IIA areas
The equipment can be used in all gas group areas
The equipment can only be used in IIB area
Rate this question:
Continue operating the machine as long as the gauge does not exceed 10% of the normal range.
Stop the machine immediately and perform a standard safety check according to the operations manual.
Adjust the pressure release valve to immediately lower the pressure to the normal operating range.
Record the pressure reading and report it to the maintenance department at the end of the shift.
Rate this question:
IP 20
IP 44
IP 54
IP 65
Rate this question:
Certified Ex d gland
Certified Ex e gland
Certified Barrier gland
Certified to IEC 60079
Rate this question:
It contains flammable materials
If the equipment is on fire it will continue to function
It will contain an internal explosion
It's too heavy to be used
Rate this question:
Flameproof
Increased safety
Purged
Intrinsically safe
Rate this question:
Close
Periodic
Frequent
Sample
Rate this question:
Group I - categories 1,2,3
Group II - Categories 1,2,3
Group III - Categories 1,2,3
Group IIII - Categories 1,2,3
Rate this question:
Circles
Cross hatching
As symbols shown on the drawing
Slanted lines
Rate this question:
Limit the maximum energy flow to apparatus
Allow any apparatus to be installed
Allow apparatus only marked Ex i to be installed
Limit the maximum temperature of the apparatus
Rate this question:
10mm
20mm
30mm
40mm
Rate this question:
All be spanner tight
Be tightened using a torque wrench set at 50Nm
Have only alternate bolts tightened
Be missing
Rate this question:
Uncertified plastic
Uncertified E1W
E1W ex e
E1W Ex d
Rate this question:
Solid particles and liquids
Solid particles and mechanical protection
Dust particles and condensation
Supply voltage and water pressure
Rate this question:
All gas groups
IIC only
IIA only
In combustible dusts only
Rate this question:
You are wearing PPE
You are working on IS circuits
The supply is SELV
The equipment Ex e
Rate this question:
Ex d II T3 T65
Ex d II 60C T3
Ex e ii T3 40degC amb
Ex e II T3 -20C<Ta<+60C
Rate this question:
IEC 60079-0
IEC 60079-10
IEC 60079-14
IEC 60079-17
Rate this question:
Ex e IIB T4
Ex n II T4
Ex d IIB T4
Ex e IIA T5
Rate this question:
Any apparatus
Simple apparatus marked Ex i
Only that specified in documentation
Only uncertified apparatus
Rate this question:
Visual
Close
Detailed
Periodic
Rate this question:
Less than 6mm
Less than10mm
Greater than 16mm
Greater than 25mm
Option 5
Rate this question:
I
IIA
IIB
IIC
Rate this question:
Flash point
Fire point
Ignition temperature
Boiling point
Rate this question:
The equipment will reach this temperature in normal operation
The equipment will reach it's flash point in normal operation
The relevant surfaces of the equipment will not reach this temperature in normal operation
The equipment will exceed the temperature rating in normal operation
Rate this question:
A,b,c
B,d,c
W,x,y
C,B,E
Rate this question:
Ex d
Ex e
Ex ia
Ex ib
Rate this question:
3mm
6mm
30mm
50mm
Rate this question:
1MΩ
100Ω
10Ω
1Ω
Rate this question:
Areas needing EPL Gc ( Cat 3G) equipment
Areas needing EPL Gb and Gc (2G & 3G) equipment
Areas needing EPL Ga (Cat 1G) equipment
Only areas needing EPL Gb (Cat 2G) equipment
Rate this question:
Zone 2 & 21
Zone 20, 21 & 22
Zone 1 & 21 and less arduous areas
Zone 0 & 20
Rate this question:
Will not reach the flashpoint of the gas in normal operation
Is deigned to reach the temperature of the T rating
Will not reach the ignition temperature of any dust or gas in normal operation
Will not exceed the temperature represented by T rating during normal or specified fault conditions
Rate this question:
X
U
A
C
Rate this question: