Low-temperature Sterilization Quiz!

10 Questions | Attempts: 692
Share

SettingsSettingsSettings
Low-temperature Sterilization Quiz! - Quiz


How much do you know about low-temperature sterilization? Ethylene oxide and vaporized hydrogen peroxide Ethylene oxide has been the most used process for sterilizing temperature and moisture-sensitive medical devices and supplies in healthcare institutions in the United States. Low-temperature sterilization is intended for use in the terminal sterilization of properly prepared metal and nonmetal devices used in healthcare facilities. This quiz will teach you about low-temperature sterilization. Good luck with the quiz.


Questions and Answers
  • 1. 

    ____________ is a byproduct of ozone sterilization.

    • A.

      Oxygen

    • B.

      Bacillus atrophaeus

    • C.

      Ethylene oxide

    • D.

      U.S food and drug administration (FDA)

    Correct Answer
    A. Oxygen
  • 2. 

    The ____________method of low-temperature sterilization uses gas cartridges for a sterlant.

    • A.

      Bacillus atrophaeus

    • B.

      Oxygen

    • C.

      Ethylene oxide

    • D.

      Sterility assurance leve

    Correct Answer
    C. Ethylene oxide
  • 3. 

    The probability of a viable microorganism being present on an item after sterilization is the _______________

    • A.

      Bacillus atrophaeus

    • B.

      Sterility assurance level

    • C.

      Ethylene oxide

    • D.

      Oxygen

    Correct Answer
    B. Sterility assurance level
  • 4. 

    The bacterial spore used to test ethylene oxide sterilization cycles is__________

    • A.

      Ethylene oxide

    • B.

      Geobacillus stearothemophilus

    • C.

      Bacillus atrophaeus

    • D.

      Oxygen

    Correct Answer
    C. Bacillus atrophaeus
  • 5. 

    Cycle time for items sterilized using ozone sterilization is __________

    • A.

      2.5 hours

    • B.

      3.0 hours

    • C.

      4.5 hours

    • D.

      6 hours

    Correct Answer
    C. 4.5 hours
  • 6. 

    An aeration time of ____________at 140 degree F is recommended for items sterilized with ethylene oxide.

    • A.

      2 hours

    • B.

      4 hours

    • C.

      6 hours

    • D.

      8 hours

    Correct Answer
    D. 8 hours
  • 7. 

    _________________________ is a bacterial spore used to test hydrogen peroxide sterilization cycle.

    • A.

      Bacillus atrophaeus

    • B.

      Geobacillus stearothermohilus

    • C.

      Oxygen

    • D.

      Ethylene oxide

    Correct Answer
    B. Geobacillus stearothermohilus
  • 8. 

    Exposure time for items sterilized using ethylene oxide sterilization is  _____________ 

    • A.

      1 hours

    • B.

      2.5 hours

    • C.

      6 hours

    • D.

      8 hours

    Correct Answer
    B. 2.5 hours
  • 9. 

    _____________________ set exposure standards for chemical sterilants.

    • A.

      EPA

    • B.

      SGNA

    • C.

      U..S. food and drug administration (FDA)

    • D.

      The occupational safety and health administration (OSHA)

    Correct Answer
    D. The occupational safety and health administration (OSHA)
  • 10. 

    __________ recommends that sterilants be rigorously tested before being marketed.

    • A.

      U.S. food and drug administration (FDA)

    • B.

      OSHA

    • C.

      EPA

    • D.

      WHO

    Correct Answer
    A. U.S. food and drug administration (FDA)

Quiz Review Timeline +

Our quizzes are rigorously reviewed, monitored and continuously updated by our expert board to maintain accuracy, relevance, and timeliness.

  • Current Version
  • Mar 15, 2022
    Quiz Edited by
    ProProfs Editorial Team
  • Aug 04, 2018
    Quiz Created by
    Deedee0704
Back to Top Back to top
Advertisement
×

Wait!
Here's an interesting quiz for you.

We have other quizzes matching your interest.