The ProProfs editorial team is comprised of experienced subject matter experts. They've collectively created over 10,000 quizzes and lessons, serving over 100 million users. Our team includes in-house content moderators and subject matter experts, as well as a global network of rigorously trained contributors. All adhere to our comprehensive editorial guidelines, ensuring the delivery of high-quality content.
Learn about Our Editorial Process
| By NCFMA
N
NCFMA
Community Contributor
Quizzes Created: 5 | Total Attempts: 20,718
| Attempts: 9,798
SettingsSettings
Please wait...
  • 1/100 Questions

    The ____________, upon finding any overcrowding conditions above the approved capacity or obstructions in aisles, passageways or other means of egress, or upon finding any condition which constitutes a life safety hazard in a building, shall be authorized to cause the event to be stopped until such condition or obstructed is corrected.

    • Police
    • Fire Code Official
    • Fire Chief
    • Health Department
Please wait...
About This Quiz

This State Certification Exam for Fire Inspector Level 1 is based upon the International Fire Code with North Carolina amendments. The International Fire Code quiz(IFC) is designed to recognize hazards related to fire, explosion, or hazardous materials. There is a list of 93 questions with multiple-choice options. Read the questions carefully and answer.

IFC Fire Inspector Exam: Hardest Quiz! - Quiz

Quiz Preview

  • 2. 

    Portable electric heaters, of all types, are __________ in any daycare.

    • Prohibited

    • Permitted

    • Allowed if approved by AHJ

    • Limited to 10,000 BTU’s

    Correct Answer
    A. Prohibited
    Explanation
    603.5.3 P55-56

    Rate this question:

  • 3. 

    Exits shall discharge directly to ___________ of the building.

    • A rated corridor

    • A vomitory

    • Atriums

    • The exterior

    Correct Answer
    A. The exterior
    Explanation
    Exits shall discharge directly to the exterior of the building in order to provide a safe and efficient means of egress during emergencies. Direct access to the exterior allows occupants to quickly evacuate the building and reach a safe location outside. This also helps to prevent congestion and delays that may occur if exits discharge to interior spaces or corridors. By discharging directly to the exterior, occupants can easily access emergency services and avoid potential hazards within the building.

    Rate this question:

  • 4. 

    Commercial cooking equipment using animal or vegetable oils shall be protected with a _______ rated portable fire extinguisher.

    • ABC

    • BC

    • Class K

    • Purple K

    Correct Answer
    A. Class K
    Explanation
    Commercial cooking equipment using animal or vegetable oils shall be protected with a Class K rated portable fire extinguisher. Class K fire extinguishers are specifically designed and effective for extinguishing fires involving cooking oils and fats. These extinguishers use a special agent that reacts with the oils to form a soapy foam, which helps to cool and smother the fire. Using a Class K extinguisher is essential in commercial kitchens to ensure the safety of both the workers and the property.

    Rate this question:

  • 5. 

    Unvented, portable fuel-fired heating equipment is prohibited in ___ occupancies.

    • A

    • E, I

    • R1, R2, R3, R4

    • All of the above

    Correct Answer
    A. All of the above
    Explanation
    Unvented, portable fuel-fired heating equipment is prohibited in all occupancies. This means that it is not allowed in any type of building or space, whether it is residential (R1, R2, R3, R4), commercial (C), industrial (I), or any other type of occupancy. The reason for this prohibition is likely due to the potential dangers and risks associated with using unvented fuel-fired heating equipment, such as the release of carbon monoxide and other harmful gases. To ensure the safety of occupants, it is important to use properly vented heating equipment in all occupancies.

    Rate this question:

  • 6. 

    Where _______, unattended self-service station is permitted.

    • Required

    • Outside Cities

    • Approved

    • Requested

    Correct Answer
    A. Approved
    Explanation
    The word "permitted" suggests that there are certain rules or regulations in place regarding the use of the self-service station. The word "approved" implies that these rules have been reviewed and authorized by the relevant authority, allowing the use of the self-service station. Therefore, "approved" is the correct answer as it aligns with the idea of the station being allowed or authorized.

    Rate this question:

  • 7. 

    An outdoor fire, for ceremonial purpose having a fuel diameter area of 3 feet or less and a height of 2 feet or less, is a/an _______________.

    • Bonfire

    • Recreational Fire

    • Open Burn

    • Rubbish Fire

    Correct Answer
    A. Recreational Fire
    Explanation
    A recreational fire is a suitable explanation for an outdoor fire used for ceremonial purposes with a fuel diameter area of 3 feet or less and a height of 2 feet or less. This type of fire is typically small and controlled, intended for enjoyment and socializing rather than waste disposal or burning rubbish.

    Rate this question:

  • 8. 

    A device, which has the appearance of life safety or fire protection equipment, but does not perform that function, shall be ___________.

    • Prohibited

    • Labeled

    • Tagged out of service

    • Painted red

    Correct Answer
    A. Prohibited
    Explanation
    A device that resembles life safety or fire protection equipment but does not actually serve that purpose should be prohibited. This is because such a device can mislead people into thinking that they are protected in case of an emergency, when in reality they are not. Prohibiting the use of such devices ensures that proper safety measures are in place and that people are not put at risk due to false appearances.

    Rate this question:

  • 9. 

    Horizontal and vertical sliding and rolling fire doors shall be inspected and tested _________ to confirm proper operation and full closure.

    • Monthly

    • Every 6 months

    • Bi-Annually

    • Annually

    Correct Answer
    A. Annually
    Explanation
    The correct answer is annually because fire doors need to be inspected and tested regularly to ensure that they are functioning properly and can fully close. Annual inspections and tests are necessary to identify any issues or malfunctions that may have occurred over time and to address them promptly to maintain the fire safety standards of the building. Regular inspections also help to prevent any potential fire hazards and ensure the overall effectiveness of the fire doors in case of an emergency.

    Rate this question:

  • 10. 

    An enclosed or separated space within a building, where hazardous chemical storage does not exceed maximum allowable quantities is a ____________.

    • Control Area

    • Chemical Storage Room

    • Cut-off Room

    • Magazine

    Correct Answer
    A. Control Area
    Explanation
    A control area is an enclosed or separated space within a building where hazardous chemical storage does not exceed maximum allowable quantities. It is a designated area that is specifically designed and equipped to safely store and handle hazardous materials. Control areas are implemented to minimize the risk of accidents and ensure the safety of individuals working in the building.

    Rate this question:

  • 11. 

    Horizontal sliding fire doors shall be tested _______ to confirm proper operation.

    • Annually

    • Bi-Annually

    • Monthly

    • Weekly

    Correct Answer
    A. Annually
    Explanation
    Horizontal sliding fire doors should be tested annually to ensure that they are functioning properly. Regular testing is necessary to ensure that the doors can effectively contain and prevent the spread of fire in the event of an emergency. By conducting annual tests, any issues or malfunctions can be identified and addressed promptly, ensuring the safety of the building and its occupants.

    Rate this question:

  • 12. 

    The required turning radius of a fire apparatus road shall be determined by the _____________.

    • Project design professional

    • Certified Engineer

    • Fire Chief

    • Fire Code Official

    Correct Answer
    A. Fire Code Official
    Explanation
    The required turning radius of a fire apparatus road is determined by the Fire Code Official. This official is responsible for enforcing fire safety regulations and ensuring that fire apparatus can access the site effectively. They have the knowledge and authority to determine the necessary specifications for the turning radius based on the specific requirements and guidelines outlined in the fire code.

    Rate this question:

  • 13. 

    When fire door hold open devices in Fire-Resistant-Rated buildings, are inoperative, the door shall be_________.

    • Wedged open

    • Locked

    • Labeled with a sign

    • Kept closed

    Correct Answer
    A. Kept closed
    Explanation
    When fire door hold open devices in Fire-Resistant-Rated buildings are inoperative, it is important to keep the door closed. This is because fire doors are designed to prevent the spread of fire and smoke in the event of a fire. By keeping the door closed, it helps to maintain the integrity of the fire-resistant barrier and ensures that the fire does not easily pass through the door.

    Rate this question:

  • 14. 

    Required fire walls, fire barriers, and fire partitions shall be ___________ to prevent the passage of fire.

    • Labeled

    • Printed

    • Maintained

    • Approved

    Correct Answer
    A. Maintained
    Explanation
    Fire walls, fire barriers, and fire partitions are designed to prevent the passage of fire and protect occupants and property. However, over time, these fire protection measures can become damaged or compromised. Therefore, it is crucial to regularly inspect and maintain them to ensure their effectiveness in preventing the spread of fire. This includes repairing any damage, replacing worn-out components, and ensuring that they are in compliance with fire safety regulations. By keeping these fire protection systems well-maintained, the risk of fire spreading can be significantly reduced.

    Rate this question:

  • 15. 

    How many chock blocks are required on a gasoline transport tanker?

    • 1

    • 2

    • 3

    • 4

    Correct Answer
    A. 2
    Explanation
    A gasoline transport tanker typically requires two chock blocks. Chock blocks are used to prevent the tanker from rolling or moving while it is parked or during loading and unloading. Placing chock blocks on both sides of the tanker helps to ensure stability and safety.

    Rate this question:

  • 16. 

    When is a repair garage required to have a sprinkler system?

    • When more than 2 stories

    • When more than 12,000 square feet

    • When in a basement

    • Any of the above

    Correct Answer
    A. Any of the above
    Explanation
    A repair garage is required to have a sprinkler system when any of the conditions mentioned in the options are met. This means that if the garage has more than 2 stories, or if it exceeds 12,000 square feet in size, or if it is located in a basement, then it must have a sprinkler system. The presence of any one of these conditions would necessitate the installation of a sprinkler system for safety purposes.

    Rate this question:

  • 17. 

    The ____________ or the fire department official in charge of an incident shall be authorized order the evacuation of any building, in which there exists any life-threatening hazard to the occupants.

    • Police department

    • Fire Code Official

    • Fire chief

    • Health department

    Correct Answer
    A. Fire Code Official
    Explanation
    The Fire Code Official is the correct answer because they are responsible for enforcing fire safety regulations and ensuring compliance with the fire code. In the event of a life-threatening hazard in a building, it is within their authority to order an evacuation to protect the occupants. The Fire Code Official has the expertise and knowledge to assess the situation and make the necessary decisions to ensure the safety of the individuals involved.

    Rate this question:

  • 18. 

    Class III standpipe systems shall be installed when the lowest floor level is ____ feet or more above the lowest level of fire department access.

    • 30

    • 40

    • 75

    • 100

    Correct Answer
    A. 30
    Explanation
    Class III standpipe systems are required to be installed when the lowest floor level is 30 feet or more above the lowest level of fire department access. This is because Class III standpipe systems are designed to provide a means for firefighters to access water on higher floors of a building during a fire incident. By requiring the installation of these systems when the lowest floor level is 30 feet or more above the lowest level of fire department access, it ensures that firefighters have a reliable water source to combat fires in tall buildings.

    Rate this question:

  • 19. 

    Which of the following structures is/are exempt from the requirements of this code?

    • One & two family residential

    • Barns on farms outside municipalities

    • Utility poles

    • All of the above

    Correct Answer
    A. All of the above
    Explanation
    All of the structures mentioned in the options are exempt from the requirements of the code. This means that they are not subject to the regulations and standards set forth in the code. One and two-family residential buildings, barns on farms outside municipalities, and utility poles are all exempt from the requirements of the code.

    Rate this question:

  • 20. 

    Fuel dispensing devices shall be _____________ the attendant at all times.

    • Under the control of

    • In clear view of

    • Shut off by

    • Within 50 feet of

    Correct Answer
    A. In clear view of
    Explanation
    Fuel dispensing devices should be in clear view of the attendant at all times. This is important for safety reasons as it allows the attendant to monitor the fueling process and quickly respond to any emergencies or malfunctions. Having the devices in clear view ensures that the attendant can easily observe and control the fueling operation, minimizing the risk of accidents or spills.

    Rate this question:

  • 21. 

    Class III standpipe systems shall be installed when the lowest floor level is ____ feet or more above the lowest level of fire department access.

    • 30

    • 40

    • 75

    • 100

    Correct Answer
    A. 30
    Explanation
    Class III standpipe systems shall be installed when the lowest floor level is 30 feet or more above the lowest level of fire department access. This means that if the lowest floor level of a building is 30 feet or higher above the level at which the fire department can access the building, a Class III standpipe system must be installed. This system provides a means for firefighters to access water on higher floors in the event of a fire, allowing them to effectively combat the fire and protect the building and its occupants.

    Rate this question:

  • 22. 

    Fire safety and evacuation plans shall be reviewed or updated _________ or as necessary.

    • Monthly

    • Quarterly

    • Annually

    • Semi-annually

    Correct Answer
    A. Annually
    Explanation
    Fire safety and evacuation plans need to be regularly reviewed or updated to ensure their effectiveness and compliance with any changes in regulations or the building's layout. The most suitable frequency for this review is annually, as it strikes a balance between being proactive in identifying any necessary updates and not overwhelming the staff with too frequent reviews. This timeframe allows for sufficient time to gather feedback, make any necessary changes, and communicate them to all relevant personnel.

    Rate this question:

  • 23. 

    What commodity class, for high piled combustible storage, are foam rubber mattresses?

    • II

    • III

    • IV

    • High Hazard

    Correct Answer
    A. High Hazard
    Explanation
    Foam rubber mattresses are classified as high hazard for high piled combustible storage. This means that they have a high potential for combustion and can contribute to the spread of fire in a storage facility. High hazard materials require special precautions and safety measures to minimize the risk of fire and ensure the safety of the storage environment.

    Rate this question:

  • 24. 

    A code official may extend any permit for a period not to exceed ______ days.

    • 5

    • 30

    • 90

    • 180

    Correct Answer
    A. 180
    Explanation
    A code official may extend any permit for a period not to exceed 180 days. This means that if there is a need for an extension on a permit, the code official can grant a maximum extension of 180 days. This allows for flexibility in case there are delays or unforeseen circumstances that prevent the completion of the project within the original permit timeframe.

    Rate this question:

  • 25. 

    The fire code requirement, for Liquefied Petroleum Gases (LPG) tank installation inspections, is the responsibility of _______________.

    • The Code Official

    • OSHA

    • NC Department of Labor

    • NC Department of Agriculture

    Correct Answer
    A. NC Department of Agriculture
    Explanation
    The correct answer is the NC Department of Agriculture. The NC Department of Agriculture is responsible for conducting inspections and enforcing regulations related to the installation of Liquefied Petroleum Gases (LPG) tanks. They ensure that proper safety measures are in place to prevent fire hazards and protect the public.

    Rate this question:

  • 26. 

    Exterior lumber piles shall not exceed ____ feet in height.

    • 20

    • 30

    • 40

    • No limit

    Correct Answer
    A. 20
    Explanation
    Exterior lumber piles should not exceed 20 feet in height. This limitation is likely in place to ensure the stability and safety of the lumber piles. Higher piles may pose a risk of collapse or instability, which could result in accidents or damage to property. By setting a maximum height of 20 feet, it helps to maintain a manageable and safe working environment.

    Rate this question:

  • 27. 

    A Class I-A liquid has a boiling point __________degrees Fahrenheit.

    • Below 72

    • Above 72

    • Below 100

    • Above 100

    Correct Answer
    A. Below 100
    Explanation
    A Class I-A liquid has a boiling point below 100 degrees Fahrenheit.

    Rate this question:

  • 28. 

    In Group E occupancies, artwork on corridor walls shall be limited to ____% of the wall area.

    • 10

    • 20

    • 30

    • 50

    Correct Answer
    A. 20
    Explanation
    In Group E occupancies, the amount of artwork on corridor walls is limited to 20% of the wall area. This restriction is in place to ensure that the corridor remains clear and unobstructed for safe evacuation in case of an emergency. Limiting the amount of artwork helps to prevent clutter and allows for better visibility and movement within the corridor.

    Rate this question:

  • 29. 

    Exterior storage of finished lumber products requires a ___ foot high-security fence.

    • 4

    • 6

    • 8

    • 10

    Correct Answer
    A. 6
    Explanation
    The correct answer is 6. Exterior storage of finished lumber products requires a 6-foot high-security fence. This height is necessary to prevent unauthorized access and theft of the lumber products. A 6-foot fence provides a significant barrier and deterrent to potential intruders, ensuring the security of the stored lumber.

    Rate this question:

  • 30. 

    What is the minimum diameter of pipe, which can be used as part of a vehicle crash protection system?

    • 2

    • 3

    • 4

    • 6

    Correct Answer
    A. 4
    Explanation
    The minimum diameter of pipe that can be used as part of a vehicle crash protection system is 4. A larger diameter pipe would provide more strength and stability to absorb the impact of a crash, making it a more effective component for protection. A smaller diameter pipe may not be able to withstand the force of a crash and could potentially fail, compromising the safety of the vehicle occupants. Therefore, 4 is the minimum diameter required for adequate crash protection.

    Rate this question:

  • 31. 

    A Class I-A liquid has a boiling point __________degrees Fahrenheit.

    • Below 72

    • Above 72

    • Below 100

    • Above 100

    Correct Answer
    A. Below 100
    Explanation
    A Class I-A liquid has a boiling point below 100 degrees Fahrenheit. This means that the liquid will start to vaporize and turn into a gas at a temperature below 100 degrees Fahrenheit.

    Rate this question:

  • 32. 

    Which of the following editions of NFPA 13 is enforcible in the State of North Carolina?

    • 2002

    • 2006

    • 2007

    • 2010

    Correct Answer
    A. 2007
    Explanation
    The correct answer is 2007 because in North Carolina, the edition of NFPA 13 that is enforceable is the 2007 edition. This means that any fire protection systems or installations must comply with the requirements and guidelines outlined in this specific edition.

    Rate this question:

  • 33. 

    Acme Print Shop has a two (2) remote, 36” exit doors. The building has a gross floor area of 6,000 square feet and is unsprinklered. Answer the following questions: What is the occupancy classification?

    • A-3

    • B

    • E

    • F

    Correct Answer
    A. B
    Explanation
    The correct answer for this question is B. The occupancy classification of the building is B. This is because the building is a print shop, which falls under the Business occupancy classification according to the International Building Code (IBC). The fact that the building has two remote exit doors and a gross floor area of 6,000 square feet does not affect the occupancy classification in this case.

    Rate this question:

  • 34. 

    You are inspecting a tenant in a strip centre Business Occupancy. There are 2,100 square feet and the maximum travel distance is 70 feet from any point to an exit door in this light hazard occupancy. Occupancy is posted at 50. Answer the following 4 questions using this scenario. How many fire extinguishers will be needed?

    • 0

    • 1, if located properly

    • 2

    • 3

    Correct Answer
    A. 1, if located properly
    Explanation
    Based on the given information, the occupancy is a light hazard occupancy with a total area of 2,100 square feet. According to fire safety regulations, for light hazard occupancies, one fire extinguisher is required for every 3,000 square feet or fraction thereof. Since the area in this scenario is less than 3,000 square feet, only one fire extinguisher is needed. However, it is important to note that the fire extinguisher should be located properly to ensure easy access in case of a fire emergency.

    Rate this question:

  • 35. 

    Common areas of Residential Occupancies are required to be inspected ________.

    • Annually

    • Every two years

    • Bi-annually

    • Never they are exempt

    Correct Answer
    A. Annually
    Explanation
    Residential occupancies are required to be inspected annually to ensure the safety and compliance of the building. This regular inspection helps identify any potential hazards, maintenance issues, or code violations that may pose a risk to the residents. By conducting these inspections annually, any necessary repairs or improvements can be made promptly, ensuring the well-being of the occupants and maintaining the overall integrity of the residential property.

    Rate this question:

  • 36. 

    Charcoal grills shall not be operated within ___ feet of combustible construction.

    • 5

    • 10

    • 15

    • 20

    Correct Answer
    A. 10
    Explanation
    Charcoal grills should not be operated within 10 feet of combustible construction. This is because charcoal grills produce heat and sparks that can potentially ignite flammable materials. Keeping a safe distance of 10 feet reduces the risk of fire and ensures the safety of the surrounding area.

    Rate this question:

  • 37. 

    The minimum stairway width of exit stairs in buildings with less than 50 occupants is _____ inches.

    • 32

    • 36

    • 44

    • 48

    Correct Answer
    A. 36
    Explanation
    The minimum stairway width of exit stairs in buildings with less than 50 occupants is 36 inches. This width is necessary to ensure that people can safely evacuate the building in case of an emergency. A wider stairway allows for easier movement and reduces the risk of overcrowding or tripping. It also provides enough space for individuals with mobility aids or disabilities to navigate the stairs comfortably. Therefore, 36 inches is the appropriate minimum width for exit stairs in smaller buildings.

    Rate this question:

  • 38. 

    What is the maximum distance from a gasoline dispenser to the emergency disconnect switch?

    • 25

    • 50

    • 75

    • 100

    Correct Answer
    A. 100
    Explanation
    The maximum distance from a gasoline dispenser to the emergency disconnect switch is 100. This means that the emergency disconnect switch should be located no more than 100 units of measurement (such as feet or meters) away from the gasoline dispenser. This distance is important to ensure that the switch can be easily accessed in case of an emergency or to quickly shut off the flow of gasoline if needed.

    Rate this question:

  • 39. 

    Is storage permitted in an unoccupied covered mall tenant space?

    • No

    • Yes

    • Yes, if the area is sprinklered

    • Yes if the ares is locked at all times

    Correct Answer
    A. No
    Explanation
    Storage is not permitted in an unoccupied covered mall tenant space.

    Rate this question:

  • 40. 

    How much gasoline, in an approved container, (for a leaf blower used to clean sidewalks), is allowed to be stored in this business?

    • None

    • 1 Gallon

    • 3 Gallons

    • Only that necessary for the operation of the leaf blower

    Correct Answer
    A. Only that necessary for the operation of the leaf blower
    Explanation
    The correct answer is "Only that necessary for the operation of the leaf blower." This means that the business is only allowed to store the amount of gasoline that is required for the leaf blower to function properly. Any excess amount of gasoline beyond what is necessary is not allowed to be stored. This is likely a safety measure to prevent the risk of accidents or fires that could occur if there is an excessive amount of gasoline stored in the business.

    Rate this question:

  • 41. 

    Charcoal grills shall not be operated within ___ feet of combustible construction.

    • 5

    • 10

    • 20

    • 25

    Correct Answer
    A. 10
    Explanation
    Charcoal grills shall not be operated within 10 feet of combustible construction. This rule is in place to prevent the risk of fire. Charcoal grills produce open flames and intense heat, which can easily ignite combustible materials such as wood, paper, or plastic. By maintaining a distance of at least 10 feet, the risk of fire spreading to nearby structures or objects is significantly reduced. This safety measure helps to protect both property and individuals from potential harm.

    Rate this question:

  • 42. 

    How often is a group R-4 Occupancy required to conduct fire drills?

    • Monthly

    • 10 per year

    • Quarterly/per shift

    • Annually

    Correct Answer
    A. Quarterly/per shift
    Explanation
    A group R-4 Occupancy is required to conduct fire drills quarterly, which means they should conduct fire drills every three months or four times a year. Additionally, the phrase "per shift" suggests that fire drills should be conducted for each shift within the occupancy, ensuring that all occupants are familiar with the emergency procedures and evacuation protocols.

    Rate this question:

  • 43. 

    What is the maximum term for a permit issued for a temporary tent location within a 12-month period on a single premise?

    • 30 Days

    • 90 Days

    • 180 Days

    • 365 Days

    Correct Answer
    A. 180 Days
    Explanation
    A permit issued for a temporary tent location can be valid for a maximum term of 180 days within a 12-month period on a single premise. This means that the permit allows the temporary tent to be set up and used for up to 180 days before it needs to be removed or renewed. This timeframe allows for a reasonable amount of time for events or activities that require a temporary tent structure without being overly restrictive or permanent.

    Rate this question:

  • 44. 

    A high piled combustible storage warehouse is 12,000 square feet. The commodity is oil base paint in metal cans stored 20 feet high. The building has 4’ draft curtains. There is NO sprinkler system. Answer the following 6 questions. How many curtained areas will this building have?

    • 2

    • 4

    • 7

    • 10

    Correct Answer
    A. 4
    Explanation
    The building will have 4 curtained areas because the total square footage of the warehouse is divided by the square footage of each curtained area. In this case, 12,000 square feet divided by the square footage of each curtained area will equal 4.

    Rate this question:

  • 45. 

    You are inspecting a tenant in a strip centre Business Occupancy. There are 2,100 square feet and the maximum travel distance is 70 feet from any point to an exit door in this light hazard occupancy. Occupancy is posted at 50. Answer the following 4 questions using this scenario. How many exit doors are required?

    • 1

    • 2

    • 3

    • 4

    Correct Answer
    A. 2
    Explanation
    Tables 1015.1 & 1021.1 P137 & 1021.1

    Rate this question:

  • 46. 

    LP-gas equipment shall be installed in accordance with __________.

    • NFPA 58

    • NFPA 59

    • Both A & B

    • None of the above

    Correct Answer
    A. Both A & B
    Explanation
    LP-gas equipment shall be installed in accordance with Both A & B, NFPA 58 and NFPA 59.
    NFPA 58: This is the Liquefied Petroleum Gas Code, which provides criteria for the storage, handling, transportation, and use of LP-gas.
    NFPA 59: This is the Utility LP-Gas Plant Code, which applies to the design, construction, location, installation, operation, and maintenance of refrigerated and non-refrigerated utility gas plants including LP-Gas containers, piping, and associated process equipment.
    Please consult with a certified professional or the equipment manufacturer for the most accurate information. Also, always follow local regulations and codes, as they may have additional or different requirements.

    Rate this question:

  • 47. 

    An unobstructed fire break passageway or fire road not less than _____ feet wide and free from guy ropes shall be maintained on all sides of tents, canopies and membranes structures.

    • 12

    • 15

    • 25

    • 50

    Correct Answer
    A. 12
    Explanation
    An unobstructed fire break passageway or fire road not less than 12 feet wide and free from guy ropes shall be maintained on all sides of tents, canopies, and membrane structures. This is necessary to ensure that there is enough space for emergency personnel to access the structures in case of a fire. A wider passageway would be even better, but the minimum requirement is 12 feet.

    Rate this question:

  • 48. 

    Flammable liquids shall not be dispensed from tanks, drums, barrels or similar containers by _______ at garages.

    • Dippers

    • Pressure

    • Gravity

    • Siphon Pumps

    Correct Answer
    A. Gravity
    Explanation
    Flammable liquids should not be dispensed from tanks, drums, barrels, or similar containers by gravity at garages. This is because gravity flow can lead to uncontrolled and potentially dangerous spills or leaks. Using dippers, pressure, or siphon pumps allows for more controlled and regulated dispensing of flammable liquids, reducing the risk of accidents or fires.

    Rate this question:

  • 49. 

    In a Group A theatre, an announcement to notify occupants of exits to use, in the event of an emergency, shall be made ____ minutes prior to starting the program.

    • 5

    • 10

    • 15

    • 20

    Correct Answer
    A. 10
    Explanation
    In a Group A theatre, an announcement to notify occupants of exits to use, in the event of an emergency, shall be made 10 minutes prior to starting the program. This allows sufficient time for the occupants to familiarize themselves with the exit routes and be prepared in case of an emergency. Making the announcement 5 minutes prior may not provide enough time for everyone to react and evacuate safely, while making the announcement 15 or 20 minutes prior may cause unnecessary disruptions or delays. Therefore, 10 minutes is the most appropriate time for this announcement.

    Rate this question:

Quiz Review Timeline (Updated): Jan 21, 2025 +

Our quizzes are rigorously reviewed, monitored and continuously updated by our expert board to maintain accuracy, relevance, and timeliness.

  • Current Version
  • Jan 21, 2025
    Quiz Edited by
    ProProfs Editorial Team
  • Jan 09, 2013
    Quiz Created by
    NCFMA
Advertisement
×

Wait!
Here's an interesting quiz for you.

We have other quizzes matching your interest.