NYC Fire Guard License Certification Exam Practice Test!

Approved & Edited by ProProfs Editorial Team
The editorial team at ProProfs Quizzes consists of a select group of subject experts, trivia writers, and quiz masters who have authored over 10,000 quizzes taken by more than 100 million users. This team includes our in-house seasoned quiz moderators and subject matter experts. Our editorial experts, spread across the world, are rigorously trained using our comprehensive guidelines to ensure that you receive the highest quality quizzes.
Learn about Our Editorial Process
| By Stewartnsh
S
Stewartnsh
Community Contributor
Quizzes Created: 1 | Total Attempts: 13,630
Questions: 25 | Attempts: 13,890

SettingsSettingsSettings
NYC Fire Guard License Certification Exam Practice Test! - Quiz

Welcome to the "NYC Fire Guard License Certification Exam Practice Test!" This comprehensive and engaging quiz is designed to help you prepare for the New York City Fire Guard License Certification Exam.

This quiz covers a broad range of topics, including fire safety regulations, emergency procedures, and the use of fire protection systems and equipment. The questions in this quiz are designed to mirror the actual exam, providing you with a realistic testing experience.

Whether you're a beginner seeking to understand the basics of fire safety or an experienced professional aiming to refresh your knowledge, this quiz serves as an Read moreexcellent resource. Remember, consistent practice is key to acing the certification exam. So, get started, challenge your understanding, and take one step closer to becoming a certified Fire Guard in New York City. Good luck!


Questions and Answers
  • 1. 

    What is the maximum distance between pull stations?

    • A.

      100 ft

    • B.

      300 ft

    • C.

      75 ft

    • D.

      200 ft

    Correct Answer
    D. 200 ft
    Explanation
    The maximum distance between pull stations is 200 ft. This is to ensure that a pull station is accessible within a reasonable distance in case of a fire.

    Rate this question:

  • 2. 

    An exit aisle of how many feet is required in all locations?

    • A.

      5 ft

    • B.

      7 ft

    • C.

      3 ft

    • D.

      9 ft

    Correct Answer
    C. 3 ft
    Explanation
    An exit aisle of 3Ft is required in all locations. This width is necessary to allow for safe evacuation during an emergency.

    Rate this question:

  • 3. 

    Fires involving flammable liquids are a class: 

    • A.

      Class A

    • B.

      Class B

    • C.

      Class C

    • D.

      Class D

    Correct Answer
    B. Class B
    Explanation
    Fires involving flammable liquids are a Class B. Class B fires involve flammable or combustible liquids, such as gasoline, kerosene, and oil.

    Rate this question:

  • 4. 

    Self closing doors must be propped open.

    • A.

      True

    • B.

      False

    Correct Answer
    B. False
    Explanation
    False, self-closing doors must not be propped open. They are designed to close automatically to prevent the spread of fire.

    Rate this question:

  • 5. 

    There must be a minimum of three pull stations per floor?

    • A.

      True

    • B.

      False

    Correct Answer
    B. False
    Explanation
    False, there is no requirement for a minimum of three pull stations per floor. The number and placement of pull stations depend on the building's size and layout.

    Rate this question:

  • 6. 

    Which pull station has a white stripe painted on it?

    • A.

      Single Action

    • B.

      Double Action

    • C.

      Interior

    • D.

      Exterior

    Correct Answer
    B. Double Action
    Explanation
    A Double Action pull station has a white stripe painted on it. This indicates that two actions are required to activate the alarm.

    Rate this question:

  • 7. 

    You must have 6 extra sprinkler heads and a wrench on property at all times.

    • A.

      True

    • B.

      False

    Correct Answer
    A. True
    Explanation
    True, you must have 6 extra sprinkler heads and a wrench on the property at all times. This is to ensure that any damaged sprinkler heads can be replaced promptly.

    Rate this question:

  • 8. 

    Which sprinkler system is used in an outdoor parking lot?

    • A.

      Wet System

    • B.

      Dry System

    • C.

      Deluge System

    • D.

      None Of The Above

    Correct Answer
    B. Dry System
    Explanation
    A Dry System is used in an outdoor parking lot. Dry systems are used in areas where water could freeze, as they only fill with water when the system is activated.

    Rate this question:

  • 9. 

    In what position is the OS&Y valve on the right in?

    • A.

      Open

    • B.

      Closed

    • C.

      Mid-Way

    • D.

      None of the above

    Correct Answer
    A. Open
    Explanation
    The OS&Y valve on the right is in the Open position. This means that water can flow through the system.

    Rate this question:

  • 10. 

    Pull stations must be mounted six feet up from the floor.

    • A.

      True

    • B.

      False

    Correct Answer
    B. False
    Explanation
    False, pull stations must be mounted at a height that is accessible to all individuals, typically around 3.5 to 4.5 feet from the floor.

    Rate this question:

  • 11. 

    The Fire Triangle includes:

    • A.

      Fuel, Heat & Air

    • B.

      Earth, Wind & Fire

    • C.

      Oxygen, Fuel & Heat

    • D.

      None of the above

    Correct Answer
    C. Oxygen, Fuel & Heat
    Explanation
    The fire triangle includes Oxygen, Fuel & Heat. These three elements are necessary for a fire to start and continue burning.

    Rate this question:

  • 12. 

    How often the pull stations must be tested?

    • A.

      Weekly

    • B.

      Monthly

    • C.

      Yearly

    • D.

      Daily

    Correct Answer
    C. Yearly
    Explanation
    Pull stations must be tested Yearly. This is to ensure that they are functioning correctly and can be relied upon in an emergency.

    Rate this question:

  • 13. 

    Fire guard log book must be kept for how long?

    • A.

      One Year

    • B.

      Two Years

    • C.

      Three Years

    • D.

      Four Years

    Correct Answer
    C. Three Years
    Explanation
    Fire Guard Log Book must be kept for Three Years. This allows for a comprehensive record of fire safety activities and incidents.

    Rate this question:

  • 14. 

    Pull stations must be painted of what color?

    • A.

      Green

    • B.

      Black

    • C.

      Purple

    • D.

      Red

    Correct Answer
    D. Red
    Explanation
    Pull stations must be painted Red. This makes them highly visible in an emergency.

    Rate this question:

  • 15. 

    In torch operations which color hose is for oxygen?

    • A.

      Green

    • B.

      Black

    • C.

      Purple

    • D.

      Red

    Correct Answer
    A. Green
    Explanation
    In torch operations, the Green hose is for Oxygen. This is a standard color-coding system used for gas cylinders and hoses.

    Rate this question:

  • 16. 

    In torch operations which color hose is for propane?

    • A.

      Green

    • B.

      Black

    • C.

      Purple

    • D.

      Black

    Correct Answer
    D. Black
    Explanation
    In torch operations, the Black hose is for Propane. This is a standard color-coding system used for gas cylinders and hoses.

    Rate this question:

  • 17. 

    In torch operations which color hose is for acetylene?

    • A.

      Green

    • B.

      Black

    • C.

      Purple

    • D.

      Red

    Correct Answer
    D. Red
    Explanation
    In torch operations, the Red hose is for Acetylene. This is a standard color-coding system used for gas cylinders and hoses.

    Rate this question:

  • 18. 

    The fire guard must first activate the fire alarm then notify the fire department?

    • A.

      True

    • B.

      False

    Correct Answer
    A. True
    Explanation
    True, the Fire Guard must first activate the Fire Alarm then notify the Fire Dept. This ensures that building occupants are alerted as soon as possible.

    Rate this question:

  • 19. 

    Is it advisable to post a false safety plan near phones to trigger false alarms for training or testing purposes intentionally?

    • A.

      Yes

    • B.

      No

    Correct Answer
    B. No
    Explanation
    No. Although, training and testing for emergency preparedness are essential, intentionally posting false safety plans near phones to trigger false alarms is not a recommended approach due to the potential negative consequences it can have on trust, resources, legality, and ethics. It's better to conduct training and testing in a transparent and responsible manner that aligns with the goals of enhancing safety and preparedness.

    Rate this question:

  • 20. 

    How often is OS&Y valve inspected?

    • A.

      Weekly

    • B.

      Monthly

    • C.

      Yearly

    • D.

      Daily

    Correct Answer
    A. Weekly
    Explanation
    The OS&Y Valve is inspected Weekly. Regular inspections ensure that the valve is in good working order.

    Rate this question:

  • 21. 

    On what class of fire do you use CO2 extinguisher?

    • A.

      Class A

    • B.

      Class B

    • C.

      Class C

    • D.

      Class D

    Correct Answer
    B. Class B
    Explanation
    On a Class B fire, you use a CO2 extinguisher. CO2 extinguishers are effective against fires involving flammable liquids.

    Rate this question:

  • 22. 

    Sprinkler heads can withstand how many pounds of pressure (PSI)?

    • A.

      16 PSI

    • B.

      15 PSI

    • C.

      200 PSI

    • D.

      500 PSI

    Correct Answer
    C. 200 PSI
    Explanation
    Sprinkler heads can withstand 200 PSI. This is the typical pressure rating for most sprinkler heads.

    Rate this question:

  • 23. 

    The fire safety plan must be approved by?

    • A.

      Fire Safety Director

    • B.

      Fire Guard

    • C.

      Fire Dept

    • D.

      Fire Safety Coordinator

    Correct Answer
    C. Fire Dept
    Explanation
    The Fire Safety Plan must be approved by the Fire Dept. This ensures that the plan meets all necessary safety regulations.

    Rate this question:

  • 24. 

    What diameter size circle on the floor do sprinkler head make using water?

    • A.

      9 Ft

    • B.

      7 Ft

    • C.

      12 Ft

    • D.

      16 Ft

    Correct Answer
    D. 16 Ft
    Explanation
    Sprinkler head makes a 16 Ft diameter circle on the floor using water. This is the typical coverage area of a standard sprinkler head.

    Rate this question:

  • 25. 

    If a building is issued a summons for lack of fire guards, how long do they have to correct it?

    • A.

      24 Hours

    • B.

      48 Hours

    • C.

      72 Hours

    • D.

      84 Hours

    Correct Answer
    C. 72 Hours
    Explanation
    If a building is issued a summons for lack of Fire Guards, they have 72 Hours to correct it. This is the standard time frame for correcting such violations.

    Rate this question:

Quiz Review Timeline +

Our quizzes are rigorously reviewed, monitored and continuously updated by our expert board to maintain accuracy, relevance, and timeliness.

  • Current Version
  • Nov 16, 2023
    Quiz Edited by
    ProProfs Editorial Team
  • Feb 12, 2011
    Quiz Created by
    Stewartnsh
Back to Top Back to top
Advertisement
×

Wait!
Here's an interesting quiz for you.

We have other quizzes matching your interest.