.
Remove actuation of the HVD through a long handle, rope or wire is permitted.
No tools must be necessary to open the HVD.
An untrained person must be able to remove the HVD withing 10 seconds when the vehicle is in ready-to- race condition.
Uttejit stole it
Rate this question:
The temparature rating for TS wiring must be at least 80 deg C.
Any shielded cable must have the shield grounded
All TS wiring that runs outside of TS enclosures must be enclosed in separate orange non-conductive conduit or an orange shielded cable.
Rate this question:
Must be constructed of a single piece of uncut, uncontinuos , closed section, steel tubing
Can be inclined more than 20 degress from vertical
Must be extended from the lowest chassis member on one side of the chassis, up, over and down to the lowest chassic member on the other side.
Rate this question:
Data logger must be inserted in the Negative TS Supply between the most negative AIR (s) and invertor.
Datalogger can be placed within the accumulator container.
Datalogger must be supplied from a additional battery.
Rate this question:
Blue flag with white dot
Blue flag
Black flag with orange dot
Rate this question:
IMD does not shutdown the TS within 30sec after insertion of test resistor between TSMP and ground
IMD shutdown the TS within 30sec after insertion of test resistor between TSMP and ground
IMD shutdown the TS within 30sec after insertion of test resistor between TS+ and TS-
Rate this question:
To each shutdown button
To the inertia switch
To the BSPD
Rate this question:
The seating mounting points must be grounding
Rotating parts of the vehicle must be grounded
Any electrical conductive part of the vehicle within 100 mm of any TS component must be grounded
Rate this question:
The vehicle to be tilted to 20 degrees
All fluids to be at their maximum fill level
All fluid containers to be deviod of any fluid
Rate this question:
Will reward the team with 10 bonus
Certifies the car is completely rule compliant
Is not a certification of complete rules compliance of the vehicle
Rate this question:
The steering wheel must have a continous perimeter that is near circular or near oval
Allowable steering system free play is limited to a total of 0.10472rad measured at the steering wheel
The steering wheel must indirectly mechanically actuate the front wheels
Rate this question:
60
50
40
30
Rate this question:
All overcurrent protection devices must be rated for the highest voltage in the system they protect, all devices used must be rated for AC
All electical systemms must have appropriate overcurrent protection
The overcurrent protection must be designed for the expected surrounding temperature range but at least for 0degrees Celsius to 85degrees celsius
Rate this question:
20Ah
30Ah
40Ah
Rate this question:
Quiz Review Timeline (Updated): Mar 21, 2023 +
Our quizzes are rigorously reviewed, monitored and continuously updated by our expert board to maintain accuracy, relevance, and timeliness.