The ProProfs editorial team is comprised of experienced subject matter experts. They've collectively created over 10,000 quizzes and lessons, serving over 100 million users. Our team includes in-house content moderators and subject matter experts, as well as a global network of rigorously trained contributors. All adhere to our comprehensive editorial guidelines, ensuring the delivery of high-quality content.
Learn about Our Editorial Process
| By Thames
T
Thames
Community Contributor
Quizzes Created: 6820 | Total Attempts: 9,511,149
| Questions: 30
Please wait...
Question 1 / 30
0 %
0/100
Score 0/100
1. Where should VAPOR BARRIERS be placed in relation to insulation?

Explanation

Vapor barriers are typically placed on the warm in winter side of insulation to prevent moisture from entering the insulated space and causing issues like mold or rot.

Submit
Please wait...
About This Quiz
Questions Quizzes & Trivia

Here are some Mixed Questions based flashcards. Learn and attempt the Mixed Questions with ease and fun with flashcards. Learn with fun and Grow.

2. What is the minimum clearance of any portion of a masonry chimney to combustibles?

Explanation

The correct minimum clearance of any portion of a masonry chimney to combustibles is 2". This clearance helps prevent combustibles from coming into contact with the hot surface of the chimney, reducing the risk of fire hazards.

Submit
3. Condensate from cooling coils or evaporators shall be conveyed from the drain pan outlet

Explanation

The correct practice is to direct condensate to an approved place of disposal to ensure proper management and prevent environmental hazards.

Submit
4. In Type IV construction, what is the minimum size of beams and girders?

Explanation

In Type IV construction, the minimum size of beams and girders is 6x10 to meet the structural requirements and provide adequate support.

Submit
5. What is the minimum thickness of an 8 foot high solid plain masonry foundation wall with 4 feet of unbalanced fill - SW soil type?

Explanation

The minimum thickness of the foundation wall should be 6 inches to support the 8 foot high structure with 4 feet of unbalanced fill, considering the SW soil type.

Submit
6. When an exposed stud cavity is found to have no insulation, what action must be taken?

Explanation

In order to ensure proper insulation throughout the building, the entire building must comply with insulation requirements, not just the specific cavity found to be lacking insulation.

Submit
7. Flammable liquids must be stored how many feet away from a structure?

Explanation

Flammable liquids must be stored at least 15 feet away from a structure to reduce the risk of fire hazards and protect the building and its occupants.

Submit
8. When fully opened, doors shall not reduce the required width by more than how many inches?

Explanation

The correct answer is 7 inches as per the regulations. Doors are required to maintain a certain width when fully opened to ensure accessibility and safety.

Submit
9. How far away from a High Hazard use group must a daycare be located?

Explanation

Daycares are required to be located a minimum of 500 feet away from High Hazard use groups to ensure the safety of children and compliance with regulations.

Submit
10. What is the minimum R-value for air supply and return ducts in an unconditioned space?

Explanation

The minimum R-value for air supply and return ducts in an unconditioned space is R6. This ensures proper insulation to prevent energy loss and maintain desired temperatures.

Submit
11. Registered professional architectural or engineering services are required for the design/construction of a ____ ft retaining wall

Explanation

Retaining walls that are 6 feet or higher typically require the expertise of registered professionals due to the structural implications and potential risks involved in their design and construction.

Submit
12. What are the minimum fasteners required for attaching a steel floor joist to the track of a load bearing wall?

Explanation

When attaching a steel floor joist to the track of a load bearing wall, the minimum requirement is 2 #8 screws. Using 4 #8 screws or 6 #8 screws is excessive and unnecessary, while 2 #10 screws may not provide sufficient strength for the connection.

Submit
13. What strong backed structural element is run at right angles to studs and joins them to make a solid member in concrete form work framing?

Explanation

In concrete form work framing, a waler is a strong backed structural element that runs at right angles to studs and joins them to make a solid member.

Submit
14. In multiple dwellings that are for rent, hire or lease but not for sale, at least 5% must be Group:

Explanation

In this context, 'Group' refers to certain types of accessible units designated specifically for persons with physical disabilities. The correct answer is A) 2A, which means at least 2 units designated for Group A must be allocated in multiple dwellings. It is important to ensure accessibility for individuals with disabilities within rental properties.

Submit
15. What is the maximum spacing for control joints in a basement?

Explanation

Control joints in a basement are typically spaced at intervals of 30 feet to help control cracking and movement in the concrete slab. Spacing them farther apart can lead to increased risks of cracks forming in the concrete.

Submit
16. A homeowner of a single-family home is exempt from the licensing provision and can pull permits for all of the following except:

Explanation

Homeowners of single-family homes can typically pull permits for smaller projects like decks and additions, but manufactured homes usually require specialized permits and licenses due to their nature.

Submit
17. A manual fire alarm is required in an office building with an occupant load of more than ____?

Explanation

The correct answer is 500 because manual fire alarms are required in office buildings with an occupant load of more than 500 for safety measures.

Submit
18. What is the minimum amount and type of nails with which wood collar ties must be face nailed to rafters?

Explanation

Wood collar ties are typically face nailed to rafters to ensure stability in roof construction. The minimum amount and type of nails required for this are 3 10d common nails. Using fewer nails or different types may compromise the structural integrity of the collar tie system.

Submit
19. Walls that separate sleeping units in the same building must comply with the provisions for _______?

Explanation

In this scenario, fire partitions are the correct answer as they are specifically designed to prevent the spread of fire from one area to another. Fire barriers, smoke partitions, and smoke barriers do not provide the same level of protection and functionality as fire partitions in this context.

Submit
20. How often should the first aid kit at a construction site be checked?

Explanation

Regularly checking the first aid kit ensures that it is well-stocked and ready for any emergencies that may arise at the construction site. Checking it weekly allows for timely replenishment of supplies and ensures that the kit is always prepared for use.

Submit
21. When insulating a structure and an existing wall cavity already has insulation, what should be done with the existing insulation?

Explanation

When an existing wall cavity already has insulation, there is no need to replace the insulation as long as it is in good condition. Testing the existing insulation or notifying the owner may not be necessary if the insulation is functioning properly.

Submit
22. A roof with a 52' span and a 6:12 slope has a rise of?

Explanation

When calculating the rise of a roof with a given span and slope, you can use the rise to run ratio from the slope. A 6:12 slope means for every 12 units of horizontal run, there are 6 units of vertical rise. In this case, for a 52' span and a 6:12 slope, the rise would be 52' / 12 * 6 = 26', making the correct answer option 26'.

Submit
23. What is the minimum required fire-resistance rating for the interior bearing walls, only supporting a roof, in a Type 1A building?

Explanation

In a Type 1A building, the minimum required fire-resistance rating for interior bearing walls supporting only a roof is 2 hours according to building codes and safety regulations.

Submit
24. When a structure has been demolished or removed, what should happen to the vacant lot?

Explanation

When a structure has been demolished or removed, the vacant lot should be filled and maintained to existing grade to ensure safety and prevent hazards.

Submit
25. Which of the following is not a permitted skylight material?

Explanation

While wired glass, fully tempered glass, and heat strengthened glass are permitted skylight materials due to their safety properties, decorative glass is not a recommended material as it may not provide the necessary safety standards for skylights.

Submit
26. What part of an open web steel joist is considered to be in tension?

Explanation

In an open web steel joist, the bottom cord is typically responsible for bearing tension forces, while the top cord bears compression forces.

Submit
27. Opening through fire walls cannot exceed ___ square feet. The aggregated width of all openings at any floor level in a non-sprinkled building shall not exceed ___% of the length of the wall.

Explanation

According to building codes and fire safety regulations, the maximum square feet for openings through fire walls is 156. Additionally, the aggregated width of all openings at any floor level in a non-sprinkled building should not exceed 25% of the length of the wall.

Submit
28. The location of plumbing piping, fixtures and equipment shall not interfere with windows or doors.

Explanation

Plumbing piping, fixtures, and equipment should not interfere with the opening and closing of doors or windows for safety and accessibility reasons.

Submit
29. Attics containing appliances do not need a clear opening and unobstructed passageway large enough for removal of the appliance

Explanation

Attics containing appliances do require a clear opening and unobstructed passageway large enough for removal of the appliance to ensure safety and ease of maintenance or replacement.

Submit
30. What information is required in a Certificate of Occupancy?

Explanation

A Certificate of Occupancy typically includes the name & address of the owner, name of the building official, and the edition of the code permit was issued under. These details are essential for verifying the compliance of the building with regulations.

Submit
View My Results

Quiz Review Timeline (Updated): Aug 4, 2025 +

Our quizzes are rigorously reviewed, monitored and continuously updated by our expert board to maintain accuracy, relevance, and timeliness.

  • Current Version
  • Aug 04, 2025
    Quiz Edited by
    ProProfs Editorial Team
  • Aug 04, 2025
    Quiz Created by
    Thames
Cancel
  • All
    All (30)
  • Unanswered
    Unanswered ()
  • Answered
    Answered ()
Where should VAPOR BARRIERS be placed in relation to insulation?
What is the minimum clearance of any portion of a masonry chimney to...
Condensate from cooling coils or evaporators shall be conveyed from...
In Type IV construction, what is the minimum size of beams and...
What is the minimum thickness of an 8 foot high solid plain masonry...
When an exposed stud cavity is found to have no insulation, what...
Flammable liquids must be stored how many feet away from a structure?
When fully opened, doors shall not reduce the required width by more...
How far away from a High Hazard use group must a daycare be located?
What is the minimum R-value for air supply and return ducts in an...
Registered professional architectural or engineering services are...
What are the minimum fasteners required for attaching a steel floor...
What strong backed structural element is run at right angles to studs...
In multiple dwellings that are for rent, hire or lease but not for...
What is the maximum spacing for control joints in a basement?
A homeowner of a single-family home is exempt from the licensing...
A manual fire alarm is required in an office building with an occupant...
What is the minimum amount and type of nails with which wood collar...
Walls that separate sleeping units in the same building must comply...
How often should the first aid kit at a construction site be checked?
When insulating a structure and an existing wall cavity already has...
A roof with a 52' span and a 6:12 slope has a rise of?
What is the minimum required fire-resistance rating for the interior...
When a structure has been demolished or removed, what should happen to...
Which of the following is not a permitted skylight material?
What part of an open web steel joist is considered to be in tension?
Opening through fire walls cannot exceed ___ square feet. The...
The location of plumbing piping, fixtures and equipment shall not...
Attics containing appliances do not need a clear opening and...
What information is required in a Certificate of Occupancy?
Alert!

Advertisement