Building Laws 07

22 Questions | Attempts: 2128
Share

SettingsSettingsSettings
Building Law Quizzes & Trivia

(Fire Code of the Philippines)
Prepared by:
Arch. /EnP. RSGabitan


Questions and Answers
  • 1. 

    The assembly of a fire door, fire window or fire damper, including all required hardware, anchorage, frames and sills.

    • A.

      Fire assembly

    • B.

      Fire protection

    • C.

      Shutter

    • D.

      Fire exit

    Correct Answer
    A. Fire assembly
  • 2. 

    A fire assembly which may remain in an open position and which will close automatically if subjected to either of the following conditions.

    • A.

      Self-closing fire assembly

    • B.

      Fire damper

    • C.

      Shutter

    • D.

      Fire protection system

    Correct Answer
    A. Self-closing fire assembly
  • 3. 

    An assembly made of incombustible material installed on openings except on exit doors and exhaust ducts for the prevention of spread of fire.

    • A.

      Damper

    • B.

      Fire exit

    • C.

      Shutter

    • D.

      Fire retardant

    Correct Answer
    C. Shutter
  • 4. 

    A bar which extends across at least one-half of each door leaf, which will open the door if subjected to pressure.

    • A.

      Flush bolt

    • B.

      Door jamb

    • C.

      Door handle

    • D.

      Panic hardware

    Correct Answer
    D. Panic hardware
  • 5. 

    This is separated from all other spaces of the building or structure by construction or equipment to provide a protected way of travel to the exit discharge.

    • A.

      Door itself

    • B.

      Exit/egress access

    • C.

      The exit

    • D.

      Exit discharge

    Correct Answer
    C. The exit
  • 6. 

    Degree of hazard is determined by: i. Fire resistance rating ii. Probability that a building, structure or facility may catch fire iii. Difficulty in evacuating people iv. Difficulty in suppressing fire

    • A.

      I, ii, iii

    • B.

      Ii, iii, iv

    • C.

      I, iii, iv

    • D.

      I, ii, iv

    Correct Answer
    B. Ii, iii, iv
  • 7. 

    An integrated system of underground or overhead piping or both connected to a source of extinguishing agent or medium which when actuated by its automatic detecting device suppresses fire.

    • A.

      Fire protective assembly

    • B.

      Fire alerting system

    • C.

      Automatic fire suppression system

    • D.

      Fire sprinkler system

    Correct Answer
    C. Automatic fire suppression system
  • 8. 

    A fire alarm system activated by the presence of a fire, where the signal is transmitted to designated locations instead of sounding a general alarm, in order to prevent panic.

    • A.

      Fire protective assembly

    • B.

      Fire alerting system

    • C.

      Automatic fire suppression system

    • D.

      Fire sprinkler system

    Correct Answer
    B. Fire alerting system
  • 9. 

    Designed to prevent spread of fire, having a fire resistance of not less than 4 hours with sufficient structural stability to remain standing even if construction on either side collapses under fire conditions.

    • A.

      Incombustible material

    • B.

      Fire wal

    • C.

      Organic coating

    • D.

      Fire retardant

    Correct Answer
    B. Fire wal
  • 10. 

    A continuous and unobstructed route of exit from any point in a building, structure or facility to a public way.

    • A.

      Means of egress

    • B.

      Stairway

    • C.

      Fire enclosure

    • D.

      Fire rating

    Correct Answer
    A. Means of egress
  • 11. 

    Any compound or mixture, which when applied properly improves the fire resistant quality of fabrics and other materials.

    • A.

      Fire coating

    • B.

      Incombustible

    • C.

      Organic coating

    • D.

      Fire retardant

    Correct Answer
    D. Fire retardant
  • 12. 

    A mechanical device consisting of linkages and a horizontal bar across a door, which when pushed from inside will case the door to open and facilitate exit from a building.

    • A.

      Flushbolt

    • B.

      Panic hardware

    • C.

      Exit handle

    • D.

      Door latch

    Correct Answer
    B. Panic hardware
  • 13. 

    A liquid mixture of binders and combustible solvents, which when spread on a surface becomes a durable protective and decorative finish.

    • A.

      Fire coating

    • B.

      Fire softener

    • C.

      Organic coating

    • D.

      Fire retardant

    Correct Answer
    C. Organic coating
  • 14. 

    Time duration that a material or construction can withstand the effect of a hundred fire test

    • A.

      Fire spread rating

    • B.

      Fire resistance rating

    • C.

      Flame spread rating

    • D.

      Flame resistance rating

    Correct Answer
    B. Fire resistance rating
  • 15. 

    Time in which flame will spread over the surface of a burning material

    • A.

      Fire spread rating

    • B.

      Fire resistance rating

    • C.

      Flame spread rating

    • D.

      Flame resistance rating

    Correct Answer
    C. Flame spread rating
  • 16. 

    A rating of combustible material based on the density and volume of smoke developed within a certain period of time when its surface is ignited.

    • A.

      Smoke resistance rating

    • B.

      Smoke spread rating

    • C.

      Smoke retardant

    • D.

      Smoke developed rating

    Correct Answer
    D. Smoke developed rating
  • 17. 

    Which of the following statements are correct? i. A door from a room to an exit or to a way of exit access shall be of the side-hinged, swinging type. ii. It shall swing with exit travel when occupied by 50+ persons or used for low hazard occupancy. iii. Access to exit shall be through a bathroom or other room subject to locking. iv. Mirrors shall not be placed in or adjacent to any exit. a) i and ii

    • A.

      I and ii

    • B.

      Iii and iv

    • C.

      I and iv

    • D.

      Ii and iii

    Correct Answer
    C. I and iv
    Explanation
    ii. It shall swing with exit travel when occupied by 50+ persons or used for HIGH hazard occupancy.
    iii. Access to exit shall NOT be through a bathroom or other room subject to locking.

    Rate this question:

  • 18. 

    Single door in a doorway for exits shall not be less than 0.71m and not more than how many meters?

    • A.

      1.05 mtrs

    • B.

      1.10 mtrs

    • C.

      1.20 mtrs.

    • D.

      1.22 MTRS.

    Correct Answer
    D. 1.22 MTRS.
  • 19. 

    When a door discharges to the outside, change in floor level shall not be more than how many millimeters?

    • A.

      202mm

    • B.

      205mm

    • C.

      207mm

    • D.

      215mm

    Correct Answer
    B. 205mm
  • 20. 

    For stairs used as exits, minimum number of risers in any one flight is ___ ?

    • A.

      2

    • B.

      3

    • C.

      4

    • D.

      5

    Correct Answer
    B. 3
  • 21. 

    A way of passage from one building to an area of refuge in another building on approximately the same level.

    • A.

      Exit passageway

    • B.

      Exit width

    • C.

      Horizontal exit

    • D.

      Discharge area

    Correct Answer
    C. Horizontal exit
  • 22. 

    Combination of an automatic or smoke detection system, automatic exhaust system and an automatic water curtain

    • A.

      Sprinkler vent method

    • B.

      Spray nozzle method

    • C.

      Rolling shutter method

    • D.

      Partial enclosure method

    Correct Answer
    A. Sprinkler vent method

Quiz Review Timeline +

Our quizzes are rigorously reviewed, monitored and continuously updated by our expert board to maintain accuracy, relevance, and timeliness.

  • Current Version
  • Jul 29, 2013
    Quiz Edited by
    ProProfs Editorial Team
  • Feb 20, 2009
    Quiz Created by
    Raegab
Back to Top Back to top
Advertisement
×

Wait!
Here's an interesting quiz for you.

We have other quizzes matching your interest.