Carpet, resilient floors, and other floor coverings in corridors
Carpets and rugs
Fire ratings of walls, structure and floor construction assemblies
Flame spread of finishes
NFPA 253/ASTM E648
ASTM D2859
ASTM E84
ASTM E2573
Carpets, resilient floors, and other corridor floor coverings
Smoke developed from flaming and nonflaming solid materials
Carpets and rugs
Site-fabricated stretch wall systems
Extent to which wall and ceiling finish contributes to fire growth
Contribution of textile wall finish to fire growth in full scale mockup
Fire ratings of walls, structure, and floor construction assemblies
Endurance test of doors to flame and heat transfer
The flame spread rating of finishes
Carpet, resilient floors, and other corridor floor coverings
Doors
Seat cushion mockup
Fire ratings of walls, strcture, and floor construction assemblies
Extent to which wall and ceiling finish (other than textiles) contributes to fire growth
Draperies, curtains, and other window treatments
ASTM E84
ASTM E119
NFPA 258
ASTM E119
NFPA 252
ASTM E84
Window assemblies
Door assemblies
Fire-resistance glazing
The mockup of a seat cushion, including foam, liner, and fabric
Separate fabric and fillings of upholstered furniture
Actual sample of a chair tested to an open flame
The mockup of a seat cushion, including foam, liner, and fabric
Separate fabric and fillings of upholstered furniture
Actual sample of a chair tested to an open flame
The mockup of a seat cushion, including foam, liner, and fabric
Separate fabric and fillings of upholstered furniture
Actual sample of chair tested to an open flame
Carpet, resilient floors, and other floor coverings in corridors
Door assemblies
Draperies, curtains, and other window treatments (banners, awnings & fabric structures)
NFPA 701
NFPA 252
NFPA 286
Class A (I)
Class B (II)
Class C (III)
Less than 450
Greater than 450
Equal to 800
In one- and two-family dwellings
Corridors/exitways of non-institutional occupancies
Corridors/exitways of institutional occupancies
A wall assembly with a 1-hour rating
A wall assembly with a 2-hour rating
A wall assembly with a 3-hour rating
Walls separating guestt rooms in Group R-1 occupancies (hotels), and R-2 and I-1 occupancies
Guest rooms separations in Type IIB, IIIB and VB buildings with auto sprinkler systems
Corridor walls
20 minutes
45 minutes
90 minutes
Exit access
Any street alley, or unobstructed parcel of land that is permanantly appropriated for public use
Exit discharge
Occupant load, occupancy of space, limitations on the common path of egress travel
Corridor width
Square footage
100'
50'
25'
.5
.2
.3
20' non-sprinklered, 50' sprinklered
10' non-sprinklered, 20' sprinklered
50' non-sprinklered, 100' sprinklered
4-1/2"
6"
3"
36" x 48"
30" x 48"
30" x 42"
36" x 42"
1:20
1:12
1:10
1:25
34"
36"
32"
30"
18" at latch side; 60" front approach
24" at latch side; 60" front approach
18" at latch side; 48" front approach
24" at latch side; 48" front approach
18" at latch side; 60" front approach
12" at latch side; 60" front approach
18" at latch side; 48" front approach
12" at latch side; 48" front approach
36" side if no obstructions within 60"; 42" and 54"
32" and 60"; 48" and 54"
36 and 60"; 48" and 54"
32" and 60"; 42" and 64"
42" front; 54" side
36" front; 54" side
40" front 48" side
36" front; 48" side
48" side; 48" front
36" side; 48" front
24" side; 48" front
12" side; 36" front
12" side; 42" front
24" side; 42" front
24" side; 54" front
12" side; 48" front
36" aff
40" aff
38" aff
32" aff
Rooftop chiller size
Wall insulation type
Window treatments
Occupancy load
An exit stairway enclosure
A theater
A hotel room
A hospital room
Sr management (client), construction PM, design PM and consulting engineers
Sr management (client), construction PM, design PM, consulting engineers and foremen from critical trades
Client rep, design PM, consulting engineers, and foremen from critical trades
Client rep, construction PM, design PM, and foremen from critical trades
Proprietary
Descriptive
Performance
Reference
Thumbnail sketches and a scale model from foam core
Multiview drawings and preliminary plans, elevations, and section drawings
Preliminary plans and elevations
Isometric and freehand plans and elevations
Cripple stud
Header
Sill
Sole plate
Heat detection
Operable windows
Building egress
Fire equipment location
Technical drawings, schedules and specifications required to price, build, and install the work
Any documents required to communicate compliance with applicable codes to local authorities responsible for issuance of permits
Technical drawings, images, and samples communicating design intent and client requirements
Detailed floor plans, ceiling plans, elevations, sections, design details, millwork drawings and material samples and specifications
A line parallel to the picture plane
A sight line projecting from the station point
A line perpendicular to the line of projection
A line representing eye-level height
Request for pricing
Letter of intent
Change order
Addendum
Red
Blue
Yellow
Green
Dimension the new receptacle to ensure the new receptacle is directly behind the other tenant's electrical box
Place the new receptacle directly adjacent to the existing receptacle with insulation to reduce sound transmission
Horizontally separate the new receptacle from the existing receptacle by 24"
Vertically align the receptacle by 24" AFF
To request an electrical contractor not listed by the contractor in the bid documents
To request pricing for an additional receptacle per the client's request
To provide additional dimensions to the contractor regarding a receptacle location
To relocate an electrical receptacle because of revised furniture plans
Demo of existing carpet, floor prep and carpet pad
Demo of existing carpet, carpet pad and base details
Carpet pad, base details and transition details
Floor prep, carpet pad and transition details