How Well You Know Me?-vivo

40 Questions

SettingsSettingsSettings
Please wait...
How Well You Know Me?-vivo


Questions and Answers
  • 1. 
    What is the meaning of VIVO 
    • A. 

       ventilation in ventilation out

    • B. 

      Breathe in breathe out

    • C. 

      I live

    • D. 

      I breathe

  • 2. 
    How do we switch between home mode and clinical mode in all the vivo devices?
    • A. 

      Press and hold on of switch simulataneously

    • B. 

      Press and hold the power and info button simultaneously 

    • C. 

      Press and hold up and down arrow button simultaneously

    • D. 

      Press and hold "+" and "-" button simultaneously

  • 3. 
    The ventilation Mode for Mouthpiece Ventilation can be VCV or PCV
    • A. 

      True

    • B. 

      False

  • 4. 
    CPAP mode in Vivo 65 can be used when
    • A. 

      A leakage circuit is used

    • B. 

      A circuit with active exhalation valve is selected

    • C. 

      The ventilator is in pediatric mode

    • D. 

      A dual limb circuit is selected

    • E. 

      The ventilator is in adult mode

  • 5. 
    The Vivo will switch Off when the user presses the ON/OFF button on the Front panel during treatment
    • A. 

      True

    • B. 

      False

  • 6. 
    Do not remove the gasket that is placed inside the Vivo 60/65 insert
    • A. 

      True

    • B. 

      False

  • 7. 
    The Alarm/Event History screen in Vivo 65 displays the _____ most recent events logged, as well as alarms that have occurred.
    • A. 

      50

    • B. 

      100

    • C. 

      150

    • D. 

      200

  • 8. 
    Which statement about the SIMV Rate setting is correct?
    • A. 

      The SIMV Rate setting is used in the SIMV ventilation modes to define the maximum number of breathes the patient will receive

    • B. 

      The SIMV Rate is defined as 80% of the patient's breathing frequency

    • C. 

      The SIMV Rate setting determines the SIMV cycle time

  • 9. 
    The "minimum inspiratory time" setting defines
    • A. 

      A minimum length for each inspiration 

    • B. 

      A minimum length for the inspiration but only for the spontaneous breaths

    • C. 

      A minimum length for the inspiration but only for the back up breaths in PSV

    • D. 

      A minimum length for each expiration

  • 10. 
    If the patient informs you that the air" comes too quick and blows too hard" it can be an idea of
    • A. 

      Increase the setting of the inspiratory Trigger from 4 to 6

    • B. 

      Decreases the setting of the Rise time from 4 to 2

    • C. 

      Increase the setting of the Rise time from 1 to 3

    • D. 

      Decrease the setting of the inspiratory Trigger from 4 to 2

  • 11. 
    The gray single limb insert shall be used for both : single-limb circuit with active exhalation valve AND single limb ckt with leakage port 
    • A. 

      True

    • B. 

      False

  • 12. 
    The dual limb insert
    • A. 

      Shall be opened and cleaned at least once per week

    • B. 

      Can only be used in hospital applications

    • C. 

      Is an integrated active exhalation valve and allows also for the flow measurement of exhaled gases

    • D. 

      Can not be used for pediatrics

  • 13. 
    How many pages are there in the monitor menu
    • A. 

      1

    • B. 

      2

    • C. 

      3

    • D. 

      4

  • 14. 
    What is the correct definition of the inspiratory pressure setting on the vivo
    • A. 

      The inspiratory pressure setting is used to define the peak airway pressure during the inspiratory phase

    • B. 

      The inspiratory pressure setting is used to define the pressure support that is delivered on top of the peep during the inspiratory phase

    • C. 

      The inspiratory pressure sets the average pressure that is delivered during the controlled breaths

  • 15. 
    Which statement is correct? the sigh frequency can occur once every
    • A. 

      25/50/100 mandatory or assisted breaths

    • B. 

      50/100/150/200/250 mandatory or assisted breaths

    • C. 

      50/100/150/200/250 mandatory breaths

    • D. 

      1, 2 or 5 mins

  • 16. 
    In VCV inspiration stops and an expiration starts in the following cases
    • A. 

      When the patient starts to exhale

    • B. 

      When the flow has decreased below the threshold or when the set Ti min is reached

    • C. 

      When the inspiration time is longer than the limit for maximal inspirational time or when the inspiration time reaches 3 seconds

    • D. 

      When the inspiration time expires or when the limit for the high pressure alarm is reached

  • 17. 
    What is the correct definition of the pressure support pressure?
    • A. 

      The support pressure settings is used in all pressure modes except the SIMV mode ventilation

    • B. 

      The SIMV support pressure settings are used in all SIMV ventilation modes, for defining the inspiratory pressure for the pressure support breaths triggered by the patients

    • C. 

      The SIMV support pressure setting is only used in the PCV-SIMV ventilation mode, for defining the inspiratory pressure for the pressure support breaths triggered by the patients

    • D. 

      The SIMV support pressure setting is only used in the VCV-SIMV ventilation mode, for defining the inspiratory pressure for the pressure support breaths triggered by the patients

  • 18. 
    Charging time for the internal battery of Vivo 50/55 and Vivo 60/65
    • A. 

      8hrs

    • B. 

      6hrs

    • C. 

      5hrs

    • D. 

      3hrs

  • 19. 
    RED color LED on the panel indicates:
    • A. 

       low priority

    • B. 

      Medium priority

    • C. 

      High priority

  • 20. 
    Vivo 3 can be used in tracheostomy patients
    • A. 

      True

    • B. 

      False

  • 21. 
    Single limb ventilator circuit with active exhalation valve can be used in Vivo 3
    • A. 

      True

    • B. 

      False

  • 22. 
    What does the high priority alarm in Vivo define
    • A. 

      3 signals followed by 2 more.the signal repeats after o.5 seconds

    • B. 

      3 signals only,with a lower frequency,the signal repeats after a 6 second pause

    • C. 

      It defines function failure

  • 23. 
    When you activate the humidifier option in Vivo, without using a humidifier chamber or humidifier circuit  what indications do you see in the machine
    • A. 

      It does not matter,machine performs normally

    • B. 

      Humidifier active

    • C. 

      Flow sensors blocked

  • 24. 
    ESync is a patented trigger technology(BREAS) that uses the information from the flow sensor to detect the effort from the patient
    • A. 

      True

    • B. 

      False

  • 25. 
    What parameters can we monitor in vivo 30/40, when the treatment is going on.
    • A. 

      PIP, PEEP, set rate

    • B. 

      EST tidal volume, total Rate, leakage

    • C. 

      Tida volume, set rate, MVe

Back to Top Back to top