We have sent an email with your new password.

Close this window

IAHCSMM

45 Questions  I  By Rdeherr
IAHCSMM
Another IAHCSMM test to help out my employees. . . . Good luck to all

  
Changes are done, please start the quiz.


Question Excerpt

Removing question excerpt is a premium feature

Upgrade and get a lot more done!
1.  The Express cycle is preset by the manufacturer for __________ minutes at 270deg F with _________ minutes of trying time and a total cycle of __________ minutes.
A.
B.
C.
D.
2.  EtO Personnel Monitoring records must be kept for 30 years after an employee has completed the last EtO-related task.
A.
B.
3.  Accreditation is a mandatory process by which an organization measures the quality of its services and performance against nationally recognized standards.
A.
B.
4.  The process of sterilizing an item that is not packaged is known as Terminal Sterilization.
A.
B.
5.  Two basic types of dry heat sterilizers are used in dental offices, which are oven type and ____________.
A.
B.
C.
D.
6.  Fire extinguishers appropriate to the hazards that is present. If the fire involved flammable liquid which type of extinguisher would you use?
A.
B.
C.
D.
7.  If the load includes complex or lumened instruments, mixed materials, or multiple instruments, a ____________ cycle at 270deg F (132deg C) should be used.
A.
B.
C.
D.
8.  Insulin is a hormone that increases the level of sugar in the blood.
A.
B.
9.  The most widely used temperature for dry heat sterilization is a minimum of 320deg F for preferably, two hours.
A.
B.
10.  There are two types of sterile solutions:____________ and external solutions.
A.
B.
C.
D.
11.  They style of sterilizer use a repeated sequence of steam flush and pressure pulse to remove air form the sterilizer chamber to process materials.
A.
B.
C.
D.
12.  Unlike gravity flash cycles, pre-vacuum flash cycles are standard sterilization cycles with a limited drying time.
A.
B.
13.  One can clean without sterilizing, but one cannot sterilize without cleaning.
A.
B.
14.  Chemicals that hold hard water minerals in solution, and prevent soaps or detergents from reacting with the minerals is known as:
A.
B.
C.
D.
15.  The process of sterilizing an items that is packaged is known as Flash Sterilization
A.
B.
16.  To test the sharpness of chisels and osteotomes, a CS tech would use_______________.
A.
B.
C.
D.
17.  Some chemical indicators are often the first performance test the user sees upon opening a sterile package.
A.
B.
18.  Sterilization______________ indicators help to confirm that package have been properly exposed to the sterilization process, and can be the first sign of a process error.
A.
B.
C.
D.
19.  Quality Assurance for EtO has process monitors that consists of the "4 R's": Run, Read, Record and ___________.
A.
B.
C.
D.
20.  Mixed EtO systems operates under a vacuum, while 100% EtO systems operate under pressure.
A.
B.
21.  Glucagon is a hormone that decreases the blood sugar level.
A.
B.
22.  Chemicals that remove or inactivate hard water minerals are known as:
A.
B.
C.
D.
23.  Specialized words or phrases known only by persons working in a position is known as Jargon.
A.
B.
24.  If the Flash sterilization load consists of a single instrument comprised of metal and without lumens, a ___________ cycle at 270deg F (132deg C) should be used.
A.
B.
C.
D.
25.  The Department of Veteran's Affairs has its own certification programs and does not follow AAMI guidelines.
A.
B.
26.  To unload a sterilizer, crack the door, and wait __________ minutes (if a vacuum unit) or _____________  minutes (if a gravity sterilizer) to assure proper evaporation and drying.
A.
B.
C.
D.
27.  There is no national recommendation for how long Central Sterile Dept needs to maintain cycle records.
A.
B.
28.  The Express cycle is a just-in-time process and has a shelf life.
A.
B.
29.  A disease, one that occurs more or less continuously throughout a community is known as:
A.
B.
C.
D.
30.  The amount of time required to kill 90% of the microorganisms present is known as:
A.
B.
C.
D.
31.  The amount of Eto that remains inside materials after sterilization is called the residual.
A.
B.
32.  Pre-set pre-vacuum flash cycle drying time helps decrease steam in the chamber and does dry the instruments.
A.
B.
33.  Bacteria that grows best in the cold is known as:
A.
B.
C.
D.
34.  Ozone is generated within the equipment so there is no need to handle sterilant containers for Ozone Sterilizers.
A.
B.
35.  A chemical process applied during instrument manufacture that provides a corrosion-resistant finish by forming a thin transparent oxide film is known as:
A.
B.
C.
D.
36.  A molecular reaction that creates an uncontrolled release of energy is known as:
A.
B.
C.
D.
37.  Non-porous and porous items within wraps, pouches, or containers can be sterilized in pre-vacuum cycles if the appropiate times and temperatures are used for each.
A.
B.
38.  Which of the following is not an ergonomic stressor?
A.
B.
C.
D.
39.  MSDS contains important information about hazardous materials that employee must know to work safely with any given material.
A.
B.
40.  Up to _______ percent of the micro-organisms on an instrument can be removed with thorough cleaning.
A.
B.
C.
D.
41.  One can clean without disinfecting, but one cannot disinfect without cleaning.
A.
B.
42.  _________ involves methods used to assess the risks of a specific activity, and to develop a program to reduce losses from exposure to them.
A.
B.
C.
D.
43.  EtO inactivates microbes by a process called__________, which seek out specific proteins in microbes to which to react.
A.
B.
C.
D.
44.  Hydrogen peroxide does not have the same inherent penetration capabilities as EtO, nor is it nearly as soluble in most materials.
A.
B.
45.  USP-NF states packaging requirements for purified water.
A.
B.
Back to top

Removing ad is a premium feature

Upgrade and get a lot more done!
Take Another Quiz