Iqn Recertification - Module (1)

8 Questions
Share

SettingsSettingsSettings
Module Quizzes & Trivia

Module (1) will test competencies on lighting systems and their components.


Questions and Answers
  • 1. 

    The SC 370d Vanguard System Controller is able to receive a universal power supply input between _____ and ______ VAC 50-60HZ

    • A.

      120 VAC

    • B.

      120 and 240 VAC

    • C.

      240 and 480 VAC

    • D.

      120 and 480 VAC

    Correct Answer
    B. 120 and 240 VAC
  • 2. 

    The FH 370x operates on ____VDC which is provided from the Vanguard SC 370x system controller TB2.

    • A.

      120

    • B.

      24

    • C.

      60

    • D.

      1000

    Correct Answer
    C. 60
  • 3. 

    The Vanguard SC370d marker interface j-box should be installed on the ground and not on the tower because the j-box houses the marker dry contacts.

    • A.

      True

    • B.

      False

    Correct Answer
    B. False
  • 4. 

    The SC 370x Vanguard system controller must be grounded with a # ___ AWG wire.

    • A.

      8

    • B.

      6

    • C.

      14

    • D.

      2

    Correct Answer
    D. 2
    Explanation
    The SC 370x system controller must be grounded with a #2AWG. The marker j-box and Flashead should be grounded with a minimum #8AWG.

    Rate this question:

  • 5. 

    The binding and discovery process should be completed on every system during an installation or if components are replaced.

    • A.

      True

    • B.

      False

    Correct Answer
    A. True
    Explanation
    Binding and discovery is a pairing process that allows the system controller to find any control boards connected to its PLC cable (Power Line Communication / Flashead cable). This process allows for configuration of the system without the need for jumpers or dip switches.

    Rate this question:

  • 6. 

    If the PCB1 controller board of the SC 370x system indicates a Day, Night, and Comm alarm what is being represented?

    • A.

      Marker Alarm

    • B.

      Commercial Power Fail

    • C.

      Beacon Comm Fail

    • D.

      Photodiode Alarm

    Correct Answer
    C. Beacon Comm Fail
    Explanation
    The most likely cause of this alarm is:
    1. The Flashead (FH 370x) is not receiving the correct DC voltage for proper operation (60VDC).
    2. The system has not been bound and discovered properly.
    3. Flashead cable termination issue.

    Rate this question:

  • 7. 

    A single SC 370d Vanguard System Controller has the ability to operate ____________________________.

    • A.

      (2) LED FH (FH 370d) and up to (8) DC LED markers

    • B.

      (1) LED FH (FH 370d) and up to (4) DC LED markers

    • C.

      (1) LED FH (FH 370d) and up to (8) DC LED markers

    • D.

      (2) LED FH (FH 370d) and up to (4) DC LED markers

    Correct Answer
    B. (1) LED FH (FH 370d) and up to (4) DC LED markers
  • 8. 

    The 1.5 Watt DC LED markers (used on the Vanguard SC 370d) operate off of ____ VDC.

    • A.

      60

    • B.

      24

    • C.

      12

    • D.

      120

    Correct Answer
    B. 24
    Explanation
    60VDC is supplied to the marker j-box (from the system controller), but the marker PCB only outputs 24VDC to operate the DC LED markers.

    Rate this question:

Quiz Review Timeline +

Our quizzes are rigorously reviewed, monitored and continuously updated by our expert board to maintain accuracy, relevance, and timeliness.

  • Current Version
  • Feb 05, 2014
    Quiz Edited by
    ProProfs Editorial Team
  • Feb 04, 2014
    Quiz Created by
Back to Top Back to top