what are the major components of X-RAY TUBE, and what does it produce?What does the Radiographer...
|
a) an X RAY TUBE PRODUCE x raysb) Major components: anode& cathodec) Supplied with electrical...
|
|
| 2 |
What is a COLLIMATOR?What do the Lead shutters control?What does the act of collimating mean?
|
a) X-RAY BEAM limiting deviceb) Lead shutters control SIZE & SHAPE of the X-RAY beam (manually...
|
|
| 3 |
What senses the size of cassette & adjusts the LIGHT FIELD?What checks the SID?
|
Positive Beam Limitation;Automatically senses the size of cassette and adjusts the LIGHT FIELD...
|
|
| 4 |
ALL COMPONENTS OF X-RAY TUBE?
|
1) Tube Column2)Cathode end3)Anode end4)X-RAY tube5)Fan housing6)Collimation controls-&...
|
|
| 5 |
WHAT IS THE TABLE & HOW IS IT CLASSIFIED?
|
*TABLE=place where the pt.lays for many exams.*Classified as:1)Tilting:90/30=>90degre in...
|
|
| 6 |
WHAT IS THE BUCKY TRAY?
|
Is a device for holding the X-RAY CASSETTE*Bucky Tray locks the cassette in place and CENTERS...
|
|
| 7 |
What is the CONTROL CONSOLE?
|
Control console: Used to turn power to the X-RAY control circuit ON/OFF*Many types of control...
|
|
| 8 |
What are the common Parts to all types of CONTROL CONSOLES?
|
1) Main Power Switch a) Supplies power to the entire X-RAY CONTROL ...
|
|
| 9 |
How KVp can be adjusted?
|
Adjustment of KVp can be either by 1 or 2 controls.1)Major= 10KVp increments2)Minor= 1 or 2...
|
|
| 10 |
WHAT DOES milliamperage( mA) control?
|
mA Milliamperage Control:a) MILLI = 0.001b) Range = 10mA - 1200 mAc) adjusted in increments...
|
|
| 11 |
What is the TIMER & what does it control?
|
TIMER: a) Units of Secondsb) Determines the lenght of exposurec) used to control the QUANTITY...
|
|
| 12 |
WHAT DOES mAs Produce & what does it control?
|
mAsProduct of mA & TIME (seconds)mA X sec. = mAsmAS =the main factor that controls...
|
|
| 13 |
WHAT IS THE TUBE STAND?
|
*Support the tube & its housing*Allows movement in various directions*Types=> (fig.8-8)*Tube...
|
|
| 14 |
What are the basic Tube Movements?
|
in RELATION TO THE TABLE:1) LONGITUDINAL2) TRANSVERSE3)VERTICAL4)ANGULATIONIN RELATION TO THE...
|
|
| 15 |
WHAT IS THE WALL MOUNTED SYSTEMS
|
a) Cassette Holderb) Bucky * Similar to table bucky * Normally...
|
|
| 16 |
What are the component ALIGNMENT
|
a) the 3 major components in the system(Tube,Table,Bucky Tray) all move INDEPENDENTLY or each...
|
|
| 17 |
Fluoroscopic Equipment?
|
Equipment used for the study of structures that are in MOTION*FLUOROSCOPY: Dynamic Radiographic...
|
|
| 18 |
FLUOROSCOPIC CONSISTS OF WHAT?
|
1) X-RAY Tube- Separate from the overhead tube discussed earlier. located BENEATH the x-ray...
|
|
| 19 |
MOBILE/PORTABLE EQUIPMENT?(fIg. 8-14)( Column, X-ray tube, Collimator housing, Cassette Bin,...
|
1) Used to perform x-ray imaging at patient.'s bedside, in surgery or in the ER 'EMERGENCY...
|
|
| 20 |
WHAT ARE THE BASIC COMPONENTS OF A DIAGNOSTIC MEDICAL X-RAY TUBE?
|
*ROTOR*STATOR COILS*ROTATING ANODE*TARGET*GLASS ENVELOPE*WINDOW*FILAMENT/FOCUSING CUP*CATHODE
|
|
| 21 |
WHAT IS SPOT FILM DEVICE & IST COMPONENTS (FIG.8-13)
|
*Component of many "Fluoro Towers"*Allows the Rad. to take STATIC images by using cassettes....
|