Definitions A court or yard that provies access to a public way for one or more exits...
|
(DEFINITIONS) Egress Court
|
|
| 2 |
Definitions Which are elements are a distinct and seperate part of the means of egress? ...
|
(DEFINITIONS) -exit discharge-exit-exit access
|
|
| 3 |
Definitions That portion of the exit access that occupants must traverse before two separate...
|
(DEFINITIONS) common path of egress travel
|
|
| 4 |
Definitions Panic hardware that is listed for use on fire door assemblies is considered...
|
(DEFINITIONS) Fire Exit
|
|
| 5 |
Definitions An alternating tread device has a series of steps that are positioned a minimum...
|
(DEFINITIONS) 50 degrees70 degrees
|
|
| 6 |
In a dining room without fixed seating, the calculated occupant load is determined by dividing...
|
(OCCUPANT LOAD)(DESIGN OCCUPANT LOAD)(MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT)(Table 1004.1.1) 15...
|
|
| 7 |
A 1,500 square foot (net) woodworking shop classroom in a high school is considered to have...
|
(OCCUPNAT LOAD)(DESIGN OCCUPANT LOAD)(MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT)(Table 1004.1.1) 30
|
|
| 8 |
For areas having seats and aisles, the occupant load for bench seating without armrests is...
|
(OCCUPANT LOAD)(FIXED SEATING) 18
|
|
| 9 |
In a fully sprinklered Group B office building having an occupant load of 3,200 occupants,...
|
(EGRESS WIDTH)(MINIMUM REQUIRED EGRESS WIDTH) 640 inches(.2)(3200)
|
|
| 10 |
A (egress) stairway serving 400 occupants in a fully-sprinklered Group I-2 hospital shall be...
|
(EGRESS WIDTH)(MINIMUM REQUIRED EGRESS WIDTH) 120(.3)(400)
|
|
| 11 |
Egress Width Multiple means of egress shall be sized so that the loss of any one means...
|
(EGRESS WIDTH)(MINIMUM REQUIRED EGRESS WIDTH) 50%
|
|
| 12 |
When fully open, a door is permitted to project into the required width of the path of egress...
|
(EGRESS WIDTH)(DOOR ENCROACHMENT) 7 inches
|
|
| 13 |
Up to 50 percent of the ceiling area of a means of egress may have a minimum ceiling height...
|
(GENERAL MEANS OF EGRESS)(PROTRUDING OBJECTS HEADROOM) 80 inches
|
|
| 14 |
General Means of Egress At a doorway, the minimum headroom clearance below any door closer...
|
(GENERAL MEANS OF EGRESS)(PROJECTING OBJECTS HEADROOM) 78
|
|
| 15 |
General Means of Egress Other than handrails serving stairs and ramps, the maximum projection...
|
(GENERAL MEANS OF EGRESS)(PROJECTING OBJECTS)(HORIZONTAL PROJECTIONS) 4
|
|
| 16 |
General Means of Egress At an exterior door not required to be accessible in a Group F-1...
|
(GENERAL MEANS OF EGRESS)(ELEVATION CHANGE) 7 inches
|
|
| 17 |
Exit signs are required so that the maximum distance from any point in an exit access...
|
(EXIT SIGNS)(WHERE REQUIRED) 100
|
|
| 18 |
Externally-illuminated exit signs shall have a minimum intensity at the face of the sign of...
|
(EXIT SIGNS)(EXTERNALLY ILLUMINATED SIGNS)(EXIT SIGN ILLUMINATION) 5
|
|
| 19 |
Performance of System Emergency lighting facilities for means of egress illumination shall...
|
(MEANS OF EGRESS ILLUMINATION)(PERFORMANCE OF SYSTEM) an average of 1 foot-candle
|
|
| 20 |
A guard need not be located along an open-sided walking surface located a maximum of _____inches...
|
(GUARDS)(WHERE REQUIRED) 30
|
|
| 21 |
In a mercantile occupancy, a required guard shall form a protective barrier a minimum of ____...
|
(GUARDS)(HEIGHT) 42
|
|
| 22 |
In areas of Group S-1 occupancy not open to a public, horizontal intermediate rails in a required...
|
(GUARDS)(OPENING LIMITATIONS) 21-inch
|
|
| 23 |
Mechanical Equipment Where a roof-top HVAC unit requiring occasional service and maintenance...
|
(GUARDS)(MECHANICAL EQUIPMENT) 10 feet
|
|
| 24 |
In a nonsprinklered building, an enclosed stairway utilized as an accessible means of egress...
|
(ACCESSIBLE MEANS OF EGRESS)(STAIRWAYS) 48
|
|
| 25 |
Accesible Means of Egress An area of refuse serving 450 occupants shall be provided with...
|
(ACCESSIBLE MEANS OF EGRESS)(AREA OF REFUGE)(SIZE) 3
|
|
| 26 |
General Means of Egress Where a barrier is installed below a protruding object having...
|
(GENERAL MEANS OF EGRESS)(PROTRUDING OBJECTS)(HEADROOM) 27
|
|
| 27 |
In all cases, the occupant load in a room or building shall not be increased beyond a maximum...
|
(OCCUPANT LOAD)(INCREASED OCCUPANT LOAD) 7
|
|
| 28 |
The means of egress in which of the following areas is required to be illuminated when the...
|
(MEANS OF EGRESS ILLUMINATION)(ILLUMINATION REQUIRED) Aisles in Groups F and S
|
|
| 29 |
Accessible Means of Egress The exterior wall adjacent to an exterior area for assisted...
|
(ACCESSIBLE MEANS OF EGRESS)(EXTERIOR AREA FOR ASSISTED RESCUE) 10
|
|
| 30 |
A tactile sign stating EXIT shall be provided adjacent to the door of all the following means...
|
(EXIT SIGNS)(TACTILE EXIT SIGN) A horiziontal exit
|
|
| 31 |
Where seating booths are provided, the occupant load shall be based on one person for each...
|
(OCCUPANT LOAD)(FIXED SEATING) 24
|
|
| 32 |
Exit Width In any position during the course of the door swing, a door is permitted to...
|
(EXIT WIDTH)(DOOR ENCROACHMENT) one-half the required width
|
|
| 33 |
Under general conditions, the means of egress illumination level shall not be less than _____...
|
(MEANS OF EGRESS)(ILLUMINATION LEVEL) 1
|
|
| 34 |
From a height of 36 inches to 42 inches in a required guard, a sphere with a maximum diameter...
|
(GUARDS)(OPENING LIMITATIONS) 4 3/8
|
|
| 35 |
Within an individual dwelling unit of a Group R-2 occupancy, openings in required guards on...
|
(GUARDS)(OPENING LIMITATIONS) 4 3/8
|