2009 IBC Sections 1001-1007, 1011 and 1013, Means of Egress I    

35 cards

2009 IBC Sections 1001-1007, 1011 and 1013, Means of Egress I


 
Password:       
 
  
Created Aug 17, 2012
by
rusotexano

 

 
Table View
 
Download
 
Print

Flashcard Set Preview

  Side A   Side B
1
Definitions A court or yard that provies access to a public way for one or more exits...
 
(DEFINITIONS) Egress Court
2
Definitions Which are elements are a distinct and seperate part of the means of egress? ...
 
(DEFINITIONS) -exit discharge-exit-exit access
3
Definitions That portion of the exit access that occupants must traverse before two separate...
 
(DEFINITIONS) common path of egress travel
4
Definitions Panic hardware that is listed for use on fire door assemblies is considered...
 
(DEFINITIONS) Fire Exit
5
Definitions An alternating tread device has a series of steps that are positioned a minimum...
 
(DEFINITIONS) 50 degrees70 degrees
6
In a dining room without fixed seating, the calculated occupant load is determined by dividing...
 
(OCCUPANT LOAD)(DESIGN OCCUPANT LOAD)(MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT)(Table 1004.1.1) 15...
7
A 1,500 square foot (net) woodworking shop classroom in a high school is considered to have...
 
(OCCUPNAT LOAD)(DESIGN OCCUPANT LOAD)(MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT)(Table 1004.1.1) 30
8
For areas having seats and aisles, the occupant load for bench seating without armrests is...
 
(OCCUPANT LOAD)(FIXED SEATING) 18
9
In a fully sprinklered Group B office building having an occupant load of 3,200 occupants,...
 
(EGRESS WIDTH)(MINIMUM REQUIRED EGRESS WIDTH) 640 inches(.2)(3200)
10
A (egress) stairway serving 400 occupants in a fully-sprinklered Group I-2 hospital shall be...
 
(EGRESS WIDTH)(MINIMUM REQUIRED EGRESS WIDTH) 120(.3)(400)
11
Egress Width Multiple means of egress shall be sized so that the loss of any one means...
 
(EGRESS WIDTH)(MINIMUM REQUIRED EGRESS WIDTH) 50%
12
When fully open, a door is permitted to project into the required width of the path of egress...
 
(EGRESS WIDTH)(DOOR ENCROACHMENT) 7 inches
13
Up to 50 percent of the ceiling area of a means of egress may have a minimum ceiling height...
 
(GENERAL MEANS OF EGRESS)(PROTRUDING OBJECTS HEADROOM) 80 inches
14
General Means of Egress At a doorway, the minimum headroom clearance below any door closer...
 
(GENERAL MEANS OF EGRESS)(PROJECTING OBJECTS HEADROOM) 78
15
General Means of Egress Other than handrails serving stairs and ramps, the maximum projection...
 
(GENERAL MEANS OF EGRESS)(PROJECTING OBJECTS)(HORIZONTAL PROJECTIONS) 4
16
General Means of Egress At an exterior door not required to be accessible in a Group F-1...
 
(GENERAL MEANS OF EGRESS)(ELEVATION CHANGE) 7 inches
17
Exit signs are required so that the maximum distance from any point in an exit access...
 
(EXIT SIGNS)(WHERE REQUIRED) 100
18
Externally-illuminated exit signs shall have a minimum intensity at the face of the sign of...
 
(EXIT SIGNS)(EXTERNALLY ILLUMINATED SIGNS)(EXIT SIGN ILLUMINATION) 5
19
Performance of System Emergency lighting facilities for means of egress illumination shall...
 
(MEANS OF EGRESS ILLUMINATION)(PERFORMANCE OF SYSTEM) an average of 1 foot-candle
20
A guard need not be located along an open-sided walking surface located a maximum of _____inches...
 
(GUARDS)(WHERE REQUIRED) 30
21
In a mercantile occupancy, a required guard shall form a protective barrier a minimum of ____...
 
(GUARDS)(HEIGHT) 42
22
In areas of Group S-1 occupancy not open to a public, horizontal intermediate rails in a required...
 
(GUARDS)(OPENING LIMITATIONS) 21-inch
23
Mechanical Equipment Where a roof-top HVAC unit requiring occasional service and maintenance...
 
(GUARDS)(MECHANICAL EQUIPMENT) 10 feet
24
In a nonsprinklered building, an enclosed stairway utilized as an accessible means of egress...
 
(ACCESSIBLE MEANS OF EGRESS)(STAIRWAYS) 48
25
Accesible Means of Egress An area of refuse serving 450 occupants shall be provided with...
 
(ACCESSIBLE MEANS OF EGRESS)(AREA OF REFUGE)(SIZE) 3
26
General Means of Egress Where a barrier is installed below a protruding object having...
 
(GENERAL MEANS OF EGRESS)(PROTRUDING OBJECTS)(HEADROOM) 27
27
In all cases, the occupant load in a room or building shall not be increased beyond a maximum...
 
(OCCUPANT LOAD)(INCREASED OCCUPANT LOAD) 7
28
The means of egress in which of the following areas is required to be illuminated when the...
 
(MEANS OF EGRESS ILLUMINATION)(ILLUMINATION REQUIRED) Aisles in Groups F and S
29
Accessible Means of Egress The exterior wall adjacent to an exterior area for assisted...
 
(ACCESSIBLE MEANS OF EGRESS)(EXTERIOR AREA  FOR ASSISTED RESCUE) 10
30
A tactile sign stating EXIT shall be provided adjacent to the door of all the following means...
 
(EXIT SIGNS)(TACTILE EXIT SIGN) A horiziontal exit
31
Where seating booths are provided, the occupant load shall be based on one person for each...
 
(OCCUPANT LOAD)(FIXED SEATING) 24
32
Exit Width In any position during the course of the door swing, a door is permitted to...
 
(EXIT WIDTH)(DOOR ENCROACHMENT) one-half the required width 
33
Under general conditions, the means of egress illumination level shall not be less than _____...
 
(MEANS OF EGRESS)(ILLUMINATION LEVEL) 1
34
From a height of 36 inches to 42 inches in a required guard, a sphere with a maximum diameter...
 
(GUARDS)(OPENING LIMITATIONS) 4 3/8
35
Within an individual dwelling unit of a Group R-2 occupancy, openings in required guards on...
 
(GUARDS)(OPENING LIMITATIONS) 4 3/8

No comments yet! Be the first to add a comment below!

Please login to post comments.
After login, we will forward you back to this flashcard.

Upgrade and get a lot more done!
Upgrade